Skip to product information
1 of 5

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

YS/T 1028.5-2015 English PDF (YST1028.5-2015)

YS/T 1028.5-2015 English PDF (YST1028.5-2015)

Regular price $270.00 USD
Regular price Sale price $270.00 USD
Sale Sold out
Shipping calculated at checkout.
Quotation: In 1-minute, 24-hr self-service. Click here YS/T 1028.5-2015 to get it for Purchase Approval, Bank TT...

YS/T 1028.5-2015: Methods for chemical analysis of lithium iron phosphate. Part 5: Determination of calcium?€?magnesium?€?zinc?€?copper?€?lead?€?chromium?€?sodium?€?aluminium?€?nickel?€?cobalt?€?manganese content. Inductively coupled plasma atomic emission spectrometry

This part of YS/T 1028 specifies the determination method of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate. This part applies to the determination of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate. The measurement range is shown in Table 1. Table 1 -- Measuring range of each element 2 Method summary The sample is dissolved with hydrochloric acid, the carbon in it is filtered out, and the element to be measured is measured by using an inductively coupled plasma atomic emission spectrometer. 3 Reagents 3.1 Hydrochloric acid (guaranteed reagent, ????????1.19 g/mL). Element Element Measuring range w / % Measuring range w / % YS/T 1028.5-2015 www.ChineseStandard.net ? Buy True-PDF ? Auto-delivery Page 5 of 9 3.2 Hydrochloric acid (1+1). 3.3 Hydrochloric acid (1+19). 3.4 Calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, manganese standard stock solutions (1000 ????g/mL). 3.5 Mix standard solutions: Respectively pipette 5 mL of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese standard stock solutions (3.4) into a 100 mL volumetric flask, dilute with hydrochloric acid (3.3) to the mark, and mix well. 1 mL of this solution contains 50 ????g of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese. 4 Instruments Inductively coupled plasma atomic emission spectrometer. Under the best working conditions of the instrument, any instrument that can achieve the following indexes can be used: -- Ligh
YS/T 1028.5-2015
YS
NONFERROUS INDUSTRY STANDARD
OF THE PEOPLE'S REPUBLIC OF CHINA
ICS 77.120.99
H 71
Methods for chemical analysis of lithium iron phosphate -
Part 5: Determination of calcium, magnesium, zinc, copper,
lead, chromium, sodium, aluminium, nickel, cobalt,
manganese content - Inductively coupled plasma atomic
emission spectrometry
ISSUED ON: APRIL 30, 2015
IMPLEMENTED ON: OCTOBER 1, 2015
Issued by: Ministry of Industry and Information Technology of PRC
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Method summary ... 4
3 Reagents ... 4
4 Instruments ... 5
5 Samples ... 6
6 Analysis steps ... 6
7 Calculation ... 7
8 Precision... 7
9 Test report ... 9
Methods for chemical analysis of lithium iron phosphate -
Part 5: Determination of calcium, magnesium, zinc, copper,
lead, chromium, sodium, aluminium, nickel, cobalt,
manganese content - Inductively coupled plasma atomic
emission spectrometry
1 Scope
This part of YS/T 1028 specifies the determination method of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate.
This part applies to the determination of the content of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt and manganese in lithium iron phosphate. The measurement range is shown in Table 1.
2 Method summary
The sample is dissolved with hydrochloric acid, the carbon in it is filtered out, and the element to be measured is measured by using an inductively coupled plasma atomic emission spectrometer.
3 Reagents
3.1 Hydrochloric acid (guaranteed reagent, ?????1.19 g/mL).
5 Samples
The particle size of the sample shall not be larger than 0.10 mm.
6 Analysis steps
6.1 Specimen
Weigh the sample (Chapter 5) according to Table 3, accurate to 0.0001 g. 6.2 Number of measurements
Weigh 2 specimens, conduct parallel measurements, and take the average value. 6.3 Blank test
Do a blank test along with the specimen.
6.4 Specimen handling
Place the specimen (6.1) in a 100 mL quartz beaker, moisten it with a small amount of water, add 20 mL of hydrochloric acid (3.2), cover it with a watch glass, and heat it at low temperature to a slight boil in a fume hood for 3 ~ 5 minutes; blow wash the watch glass with a small amount of water, filter with filter paper after cooling, and wash the filter residue with water 5 ~ 7 times; transfer the filtrate into a volumetric flask according to the corresponding test solution volume in Table 3, dilute with water to the mark, mix well for later use; at the same time, make a reagent blank.
6.5 Drawing of working curve
Accurately pipette 0 mL, 0.40 mL, 1.00 mL, 2.00 mL, 5.00 mL, 10.00 mL, and 20.00 mL of mixed standard solution (3.5) into 100 mL volumetric flasks, dilute to the mark with hydrochloric acid (3.3), and mix well. On the ICP spectrometer with optimized parameters, measure the spectral intensity of each element such as calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese, and draw a working curve.
6.6 Determination
On the ICP spectrometer with optimized parameters, measure the spectral intensity of calcium, magnesium, zinc, copper, lead, chromium, sodium, aluminium, nickel, cobalt, and manganese in the blank solution and sample solution, and obtain the concentrations of corresponding components from the working curve. For the sample whose element content exceeds the concentration range of the working curve, it can be measured after quantitative dilution.
7 Calculation
The content of the element to be measured is calculated based on the mass fraction wx of the element to be measured, and the value is expressed in % and calculated according to formula (1):
where:
?? -- The concentration of the measured element in the test solution obtained from the working curve, in micrograms per milliliter (??g/mL);
??0 -- The concentration of the measured element in the blank solution obtained from the working curve, in micrograms per milliliter (??g/mL);
m -- The mass of the specimen, in grams (g);
V -- The volume of the test solution, in milliliters (mL).
The calculation results are rounded to two decimal places.
8 Precision
8.1 Repeatability
The measured values of two independent test results obtained under repeatability conditions are within the average value range given below; the absolute difference between the two test results does not exceed the repeatability limit (r), the probability of exceeding the repeatability limit (r) does not exceed 5%, and the repeatability limit (r) is obtained by linear interpolation according to the data in Table 4:

View full details