YD/T 1644.1-2007: Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p

Delivery: 9 seconds. Download (and Email) true-PDF + Invoice.
Get Quotation: Click YD/T 1644.1-2007 (Self-service in 1-minute)
Newer / historical versions: YD/T 1644.1-2007

Preview True-PDF


Scope

This Standard defines the procedure to determine the specific absorption rate (SAR) for
hand-held devices used in close proximity to the ear.
It applies to any electromagnetic field (EMF) transmitting device intended to be used
with the radiating part of the device in close proximity to the human head and held against the
ear, including mobile phones, cordless phones, etc. The frequency range is 300 MHz to 3
GHz.
The objective of this Standard is to specify the measurement method for demonstration
of compliance with the specific absorption rate (SAR) limits for such devices. The standard
is about the measurement method, rather than the safety thresholds.

Basic Data

Standard ID YD/T 1644.1-2007 (YD/T1644.1-2007)
Description (Translated English) Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices-Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close p
Sector / Industry Telecommunication Industry Standard (Recommended)
Classification of Chinese Standard M04
Classification of International Standard 33.100
Word Count Estimation 80,892
Date of Issue 2007-07-20
Date of Implementation 2007-12-01
Adopted Standard IEC 62209-1-2005, IDT
Regulation (derived from) MIIT Science [2007] No. 343
Issuing agency(ies) Ministry of Information Industry of the People's Republic of China
Summary This standard specifies the use of emission portion close to the ear using a handheld wireless communication device specific absorption rate assessment procedures. This standard applies to the operating frequency range of 300MHz-3GHz arbitrary electromagnetic field emission devices, such as: mobile phones, cordless phones and so on. The purpose of this section is to demonstrate how safety limits according to the corresponding measuring device under test SAR value, this part is just a method of electromagnetic radiation measurement standards, rather than on a standard safety limits.