HJ/T 373-2007: Technical specifications of quality assurance and quality control for monitoring of stationary pollution source(on trial)

This Standard specifies technical requirements for quality assurance and quality control of sampling and testing in the process of manually monitoring and comparison monitoring of This Standard specifies technical requirements for quality assurance and quality control of sampling and testing in the process of manually monitoring and comparison monitoring of waste water discharge and exhaust emission of stationary pollution source. This Standard applies to the environmental monitoring of waste water discharge and exhaust emission of stationary pollution sources.
HJ/T 373-2007
HJ
INDUSTRY STANDARD
OF THE PEOPLE REPUBLIC OF CHINA
Technical specifications of quality assurance
and qualify control for monitoring of stationary
pollution source (on trial)
ISSUED ON. NOVEMBER 12, 2007
IMPLEMENTED ON. JANUARY 1, 2008
Issued by. State Environmental Protection Administration
Announcement of State Environmental Protection
Administration
2007 No. 72
In order to implement Environmental Protection Law of the PEOPLE Republic of China, to protect environment, ensure human health, specify the supervision and management of environmental pollution source and improve the accuracy and reliability of monitoring data, hereby approve and issue two standards, including The technical requirement and test procedure for Water Quality Automatic Sampler as national environmental protection industry standard.
The standard name and standard number are as follows.
I. ?€?The Technical Requirement and Test Procedure for Water Quality Automatic Sampler?€? (HJ/T372-2007)
II. Technical specifications of quality assurance and qualify control for monitoring of stationary pollution source (on trial) (HJ/T 373-2007)
The above standards shall be a directive standards, be implemented since January 1, 2008, and be published by the China Environmental Science Press, and the content of the standards is available at the website of State Environmental Protection Administration It is hereby to announce.
November 12, 2007
Table of Contents
1 Scope of application ... 5
2 Normative references ... 5
3 Terms and definitions ... 6
4 The technical requirements of quality assurance and quality control for waste water monitoring ... 6
4.1 Monitoring personnel ... 6
4.2 Monitoring instruments and equipment ... 7
4.3 Verification of working condition ... 8
4.4 Sample collection ... 9
4.5 The basic conditions of analytical laboratory ... 10
4.6 Quality control of laboratory analysis ... 10
4.7 Standard samples and chemical reagents ... 17
4.8 Measurement of the amount ... 17
4.9 Monitoring report ... 17
4.10 Waste water online monitoring system contrastive monitoring quality assurance and quality control technology requirements ... 18
5 The technical requirements of quality assurance and quality control for exhaust gas monitoring ... 18
5.1 Tester ... 18
5.2 Monitoring instruments and equipment ... 18
5.3 Working condition verification ... 20
5.4 Sample collection ... 25
5.5 Quality control of laboratory analysis ... 27
5.6 Standard samples and chemical reagents ... 27
5.7 Monitoring report ... 27
5.8 Flue gas online monitoring system contrastive monitoring quality
assurance and quality control technology requirements ... 27
Annex A (Informative) Records of quality assurance and quality control for monitoring of stationary pollution source ... 29
Annex B (Informative) Verification methods of boiler operating load ... 35 Foreword
In order to implement Environmental Protection Law of the PEOPLE Republic of China, Water Pollution Prevention and Control Law of the PEOPLE Republic of China and Atmospheric Pollution Prevention Law of the PEOPLE Republic of China, standardize the monitoring of pollution source, and ensure the accuracy and reliability of monitoring data and information, hereby formulate this Standard.
This Standard specifies technical requirements for quality assurance and quality control of sampling and testing in the process of manually monitoring and comparison monitoring of waste water discharge and exhaust emission of stationary pollution source. This Standard is a directive standard.
This Standard is proposed by the Department of Science, Technology and Standards of State Environmental Protection Administration.
Drafting organizations of this Standard are. China National Environmental Monitoring Center, and Shenyang Municipal Environmental Monitoring Center.
This Standard was approved by State Environmental Protection Administration on November 12, 2007.
This Standard was implemented on January 1, 2008.
State Environmental Protection Administration shall be responsible for interpreting this Standard.
Technical specifications of quality assurance
and qualify control for monitoring of stationary
pollution source (on trial)
1 Scope of application
This Standard specifies technical requirements for quality assurance and quality control of sampling and testing in the process of manually monitoring and comparison monitoring of waste water discharge and exhaust emission of stationary pollution source. This Standard applies to the environmental monitoring of waste water discharge and exhaust emission of stationary pollution sources.
2 Normative references
The articles contained in the following documents have become part of this Standard when they are quoted herein. For the undated documents so quoted, all the modifications or revisions made thereafter shall be applicable to this Standard.
GB 8978-1996 Integrated wastewater discharge standard
GB 12998-91 Water quality???Guidance on sampling techniques
GB 16297-1996 Comprehensive emission standard of air pollutants
GB/T 16157-1996 The determination of particulates and sampling methods of gaseous pollutants emitted from exhaust gas of stationary source
HJ/T 75-2007 Specifications for continuous emissions monitoring of flue gas emitted from stationary sources (on trial)
HJ/T 76-2007 Specification and test procedure for continuous emission monitoring systems of flue gas emitted from stationary sources (on trial)
HJ/T 91-2002 Technical specifications requirements for monitoring of surface water and waste water
HJ/T 92-2002 Technical requirements for monitoring of total amount of pollutants in waste water
HJ/T 355-2007 Technical specifications for the operation and assessment of Wastewater on-line monitoring system (on trial)
HJ/T 356-2007 Technical specifications for validity of wastewater on-line monitoring data (on trial)
Check-up System of Employment with Certificates for Environmental Monitoring Staff (Huanfa [2006] No.114)
3 Terms and definitions
For the purpose of this Standard, the following terms and definitions shall apply. 3.1 Quality assurance
The total quality management during the process of environment monitoring includes all activities and measures to ensure the accuracy and reliability of environmental monitoring data.
3.2 Quality control
It refers to the operational techniques and activities adopted to meet the quality requirements of environmental monitoring.
3.3 Comparison monitoring
It refers that in order to verify the accuracy of results of water and gas online automatic monitor, manual monitoring method and online automatic monitor method are simultaneously adopted; manual monitoring results are the basis for verifying online automatic monitoring data. Of which the manual monitoring methods shall use national standard methods or other currently effective methods.
3.4 Field-laboratory quality control
It refers to the process of synchronous sampling and analysis of quality control samples and practical samples according to fixed routines. And its quality control results can be used to determine whether the error of the monitoring results derives from field sampling or laboratory analysis.
4 The technical requirements of quality assurance and quality control for waste water monitoring
4.1 Monitoring personnel
When water is deeper than 1 m, sampling shall be conducted at 1/4 depth of water under surface layer; when depth of water is not more than 1 m, sampling shall be conducted at 1/2 depth of water; the sampling location shall be close to the center of sampling section and comply with the requirements of 6.3.2 in HJ/T92-2002.
4.4.5 Sampling apparatus
4.4.5.1 Requirements of sampling apparatuses
Sampling apparatuses shall be able to mark the sampling depth, and texture and structure shall comply with the provisions of GB 12998-91.
4.4.5.2 Cleaning of sampling apparatuses
The sampling a...