GB/T 34845-2017: Tissue paper -- Determination of absorbable organic halogen (AOX)

This standard specifies the determination method for adsorbable organic halogens (AOX) in tissue paper. This standard applies to the determination of AOX in tissues, toilet paper and other tissue papers. The detection limit of this standard is 2 mg/kg.
GB/T 34845-2017
GB
NATIONAL STANDARD OF THE
PEOPLE REPUBLIC OF CHINA
ICS 85.080
Y 30
Tissue paper - Determination of adsorbable organic
halogen (AOX)
ISSUED ON: NOVEMBER 01, 2017
IMPLEMENTED ON: MAY 01, 2018
Issued by: General Administration of Quality Supervision, Inspection and Quarantine;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 4
4 Principle ... 5
5 Apparatus and equipment ... 5
6 Reagents and materials ... 5
7 Sampling and processing ... 6
8 Test procedure ... 6
9 Result calculation ... 7
10 Inspection and calibration ... 7
11 Test report ... 8
Tissue paper - Determination of adsorbable organic
halogen (AOX)
1 Scope
This standard specifies the determination method for adsorbable organic halogens (AOX) in tissue paper.
This standard applies to the determination of AOX in tissues, toilet paper and other tissue papers.
The detection limit of this standard is 2 mg/kg.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 450 Paper and board - Sampling for testing and identification of
machine and cross direction wire side and felt side
GB/T 462 Paper, board and pulp - Determination of moisture content of
analytical sample
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Tissue paper
Crepe paper for sanitary wipes produced from wood fiber or non-wood fiber, including toilet paper, paper towels (paper napkins, paper face towels, paper handkerchiefs), hand tissues, kitchen paper towels, etc.
3.2
Adsorbable organic halogen; AOX
6.4 Activated carbon: Dedicated for determination of adsorbable organic halogen (AOX).
6.5 Electrolyte: Measure 75 mL of 98% glacial acetic acid; add water to make the volume to 100 mL.
6.6 Hydrochloric acid solution: 0.010 mol/L; measure 32.57 mL of 0.307 mol/L hydrochloric acid (density at 1.19 g/mL); add water to make the volume to 1 L. 6.7 p-chlorophenol stock solution: 200 ??g/L; weigh 72.5 mg of p-chlorophenol; add water to make the volume to 100 mL.
6.8 Compressed gas: It is necessary to dilute oxygen with inert gas to control combustion during combustion. All gases used in the test shall not contain any form of chlorine and bromine.
7 Sampling and processing
7.1 Sampling shall be carried out in accordance with the provisions of GB/T 450. 7.2 Test the moisture of the sample in accordance with the provisions of GB/T 462.
7.3 Preparation of the specimen: Use tweezers or scissors to tear or cut the sample into small pieces. Protective gloves shall be worn during specimen collection and preparation, to prevent contamination of the specimen.
8 Test procedure
8.1 Weigh 0.4 g ~ 0.6 g (accurate to 1 mg) of specimen. Put it into a 250 mL conical flask (5.4). Add 100 mL of sodium nitrate working solution (6.2). Close the stopper and shake the conical flask vigorously to make specimen is fully moistened. Then place it on the oscillator (5.2). Oscillate at a speed of 150 times/min for 1 h.
8.2 After oscillation, use the filter device (5.3) that has been installed in a clean quartz cup filter to filter the contents of the conical flask; use 25 mL of sodium nitrate working solution to rinse the conical flask and the inner wall of the filter. Collect all the filtrate in a clean conical flask. Keep the filtrate A for later use. 8.3 Add 50 mg of activated carbon (6.4) to the filtrate A. Cap the flask tightly. Then place it on the oscillator, to oscillate it at a speed of 150 times/min for 1 h. 8.4 Use a filter device to filter the contents of the conical flask to another clean quartz cup. Use 25 mL of sodium nitrate working solution to rinse the conical