PayPal, credit cards. Download editable-PDF & invoice In 1 second!
GB/T 27985-2011 English PDF (GBT27985-2011)
GB/T 27985-2011 English PDF (GBT27985-2011)
Couldn't load pickup availability
GB/T 27985-2011: Determination of tannin in feeds -- Spectrophotometry
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 65.120
B 46
Determination of tannin in feeds - Spectrophotometry
ISSUED ON: DECEMBER 30, 2011
IMPLEMENTED ON: JUNE 01, 2012
Issued by: General Administration of Quality Supervision, Inspection and Quarantine;
Standardization Administration of the People’s Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Principle ... 4
4 Reagents and solutions ... 4
5 Instruments and equipment ... 5
6 Sample preparation ... 6
7 Analysis steps ... 6
8 Calculation and expression of results ... 7
9 Repeatability ... 7
Determination of tannin in feeds - Spectrophotometry
1 Scope
This Standard specifies the spectrophotometry for the determination of tannin in feeds. This Standard applies to the determination of tannin content in compound feeds and single feeds.
The detection-limit of this method is 17.5 mg/kg, and the linear range is 0.50 mg/L ~ 6.00 mg/L.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies to this document. For undated references, the latest edition (including any amendment) applies to this document.
GB/T 6682, Water for analytical laboratory use - Specification and test methods GB/T 14699.1, Feeding stuffs - Sampling
GB/T 20195, Animal feeding stuffs - Preparation of test samples
3 Principle
Use acetone solution to extract tannin compounds in the feed; after filtration, take the filtrate, add sodium tungstate-phosphomolybdic acid mixed solution and sodium carbonate solution; after color development, use the reagent as a blank control; use a spectrometer to determine the absorbance value at a wavelength of 760 nm; use tannic acid as a standard curve to determine the tannin content in the feed.
4 Reagents and solutions
Unless otherwise specified, the reagents used in this Standard shall be analytical reagents, and the water shall comply with the provisions of GB/T 6682 for grade-3 water.
4.1 Sodium tungstate (Na2O4W·2H2O).
4.2 Phosphomolybdic acid (H3Mo12O40P·XH2O).
5.8 Erlenmeyer flask with stopper: 250 mL.
5.9 Medium-speed quantitative filter paper.
6 Sample preparation
Take samples according to GB/T 14699.1; prepare samples according to GB/T 20195. Grind them; pass them through a 0.45 mm sieve; mix well; put them in airtight containers; store them at low temperature in the dark for future use.
7 Analysis steps
7.1 Preparation of test solution
Weigh 1 g ~ 2 g of the sample (accurate to 0.000 1 g); put it into a 250 mL Erlenmeyer flask with stopper (5.8); add 50.00 mL of acetone solution (4.7) accurately; seal it with a stopper; place it on an oscillator (5.4) and shake for 40 min; let it stand still; use medium-speed quantitative filter paper (5.9) to filter; discard the initial filtrate, and continue the filtration for determination.
7.2 Determination
7.2.1 Drawing of the standard curve
Accurately measure 0.00 mL, 0.50 mL, 1.00 mL, 2.00 mL, 3.00 mL, 4.00 mL, 5.00 mL and 6.00 mL of tannic acid standard solution (4.10); respectively put them into 50 mL volumetric flasks filled with about 30 mL of water; shake well; add 2.5 mL of sodium tungstate-phosphomolybdic acid mixed solution (4.3); add 5.0 mL of sodium carbonate solution (4.5); shake well; use water to dilute to 50 mL respectively; shake well. The concentration of tannic acid standard solution is 0.00 mg/L, 0.50 mg/L, 1.00 mg/L, 2.00 mg/L, 3.00 mg/L, 4.00 mg/L, 5.00 mg/L and 6.00 mg/L respectively. Let it stand for 30 min; after color development, use 0.00 mg/L of the standard curve as the blank; measure the absorbance of the standard solution at a wavelength of 760 nm; draw the standard curve with the concentration of tannin as the abscissa and the absorbance value as the ordinate.
7.2.2 Determination of sample
Accurately measure 1.00 mL of the test solution (7.1); put it into a 50 mL volumetric flask filled with about 30 mL of water; shake well; add 2.5 mL of sodium tungstate- phosphomolybdic acid mixed solution (4.3); add 5.0 mL of sodium carbonate solution (4.5); shake well; use water to dilute to 50 mL; shake well. Let it stand for 30 min to develop color; then, use 0.00 mg/L of the standard curve as a blank; measure the absorbance of the sample solution at a wavelength of 760 nm; obtain the concentration of tannin in the test solution (7.1) according to the standard curve. If the absorbance