GB/T 17143.7-1997: Information technology. Open Systems Interconnection. Systems Management. Part 7: Security alarm reporting function
Delivery: 9 seconds. Download (and Email) true-PDF + Invoice.Get Quotation: Click GB/T 17143.7-1997 (Self-service in 1-minute)
Newer / historical versions: GB/T 17143.7-1997
Preview True-PDF
Scope
This Standard defines the security alarm reporting function. The security alarmreporting function is a systems management function which may be used by an
application process in a centralized or decentralized management environment
to exchange information for the purpose of systems management, as defined
by GB/T 9387.4. This Standard is positioned in the application layer of GB 9387
and is defined according to the model provided by GB/T 17176. The role of
systems management functions is described by GB/T 17142. The security
alarm notifications defined by this systems management function provide
information regarding operational condition and quality of service, pertaining to
security.
Security-related events are of relevance to the provision of security. The
security policy determines the actions to be undertaken whenever a security-
related event has occurred The security policy may, for example, specify that a
security alarm report be generated, a record of the event be made in a security
audit trail, a threshold counter be incremented, the event be ignored, or a
combination of these actions be taken. This Standard is only concerned with
security alarm reporting.
This Standard
- establishes user requirements for the service definition needed to support
the security alarm reporting function;
- defines the service provided by the security alarm reporting function;
- specifies the protocol that is necessary in order to provide the service;
- defines the relationship between the service and management
notifications;
- defines relationships with other systems management functions;
- specifies conformance requirements.
This Standard does not
- define the nature of any implementation intended to provide the security
alarm reporting function;
- specify the manner in which management is accomplished by the user of
the security alarm reporting function;
- define the nature of any interactions which result in the use of the security
alarm reporting function;
- specify the services necessary for the establishment, normal and
abnormal release of a management association;
- define any other notifications, deked by other standards, which may be of
interest to a security administrator.
Basic Data
Standard ID | GB/T 17143.7-1997 (GB/T17143.7-1997) |
Description (Translated English) | Information technology. Open Systems Interconnection. Systems Management. Part 7: Security alarm reporting function |
Sector / Industry | National Standard (Recommended) |
Classification of Chinese Standard | L79 |
Classification of International Standard | 35.100.70 |
Word Count Estimation | 14,128 |
Date of Issue | 12/15/1997 |
Date of Implementation | 8/1/1998 |
Adopted Standard | ISO/IEC 10164-7-1992, IDT |
Issuing agency(ies) | State Bureau of Technical Supervision |
Summary | This standard specifies the security alarm reporting function. Security alarm reporting function is a systems management functionality that the application process available to exchange information in a centralized or decentralized management environment for use in GB/T 9387. 4 defined systems management. The standard application layer situated GB 9387, according to GB model definition/T 17176 provides. The role of systems management functions described by GB/T 17142. Provide information about the operating conditions and the quality of service of the notice by the security alarm system management functions defined, they are attached to safety. |