Skip to product information
1 of 7

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

GB 4208-2008 English PDF (GB4208-2008)

GB 4208-2008 English PDF (GB4208-2008)

Regular price $150.00 USD
Regular price Sale price $150.00 USD
Sale Sold out
Shipping calculated at checkout.
Delivery: 3 seconds. Download true-PDF + Invoice.Newer version: (Replacing this standard) GB/T 4208-2017
Get QUOTATION in 1-minute: Click GB 4208-2008
Historical versions: GB 4208-2008
Preview True-PDF (Reload/Scroll if blank)

GB 4208-2008: [GB/T 4208-2008] Degrees of protection provided by enclosure (IP code) [Renamed to GB/T 4208-2008]
GB 4208-2008
Degrees of protection provided by enclosure (IP code)
ICS 13.260
K09
National Standards of People's Republic of China
GB 4208-2008/IEC 60529.2001
Replacing GB 4208-1993
Shell protection (IP code)
(IEC 60529.2001, IDT)
Published 2008-03-25
2009-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China issued
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
And a range of object 1
2 Normative References 1
Terms and definitions 1 3
4 Identification 3
Prevent access to hazardous parts and against solid foreign objects protection rating of 5 indicated by a characteristic numeral 5
6 wherein the second digital to prevent water entering the indicated level of protection 6
Prevent access to hazardous levels of protection member 77 indicated by additional letter
8 8 Supplementary letters
Example 9 IP identification code 8
10 logo 9
General requirements 11 Test 9
Protection of access to hazardous parts 12 first tests indicated a characteristic numeral 10
Test against solid foreign matter into the first characteristic numeral 13 indicated 12
14 wherein the second digital to prevent water entering the test indicated 13
Test access to hazardous protection member 15 indicated by 16 additional letter
Annex A (normative) verify voltage equipment to prevent access to hazardous sample IP code member 22
Content Appendix B (Informative Appendix) can be used as specified in the relevant product standard 27
Reference 28
Hinge means 17 again FIG. 1
FIG 2 test dust test apparatus (dust box) 18
FIG 3 Test vertical drip test device (drip box) 19
FIG 4 wherein the second test numbers 3 and 4, water spray and splash proof tester (pendulum tube) 20
FIG 5 wherein the second test numbers 3 and 4, water spray and splash proof handheld testing device (head) 20
FIG 6 Test anti-spray test apparatus (hose nozzle) 21
Table protection level of access to hazardous parts 1 wherein a first number represented 5
Table against solid foreign objects protection rating of 2 indicated by a numeral 6 wherein
Table 3 preventing water from entering the second level of protection represented by the numeral 7 wherein
Table Protection Level 7 dangerous proximity member 4 indicated by additional letter
Protection class Test conditions shown in Table 5, represented by the characteristic numeral 9
Table 6 prevent access to hazardous parts person touches test with 11
Table 7 Test Method for preventing foreign matter from entering the solid 12
Table 8 Test Waterproof test conditions and main methods 13
Table 9 Press IPX3 IPX4 test conditions and the total water flow q v 15
Table A. IP sample code to verify access to hazardous member 1 to prevent the low voltage apparatus 22
GB 4208-2008/IEC 60529.2001
Foreword
All technical contents of this standard is mandatory.
This is equivalent to using the standard IEC 60529.2001 "shell protection (IP code)" (in English).
This standard and IEC 60529.2001 for editorial differences. the abolition of IEC foreword and introduction, increasing our standard preface and
introduction.
Instead of the standard GB 4208-1993 "shell protection (IP code)"; this standard and major changes in GB 4208-1993
as follows.
a) an increase of introduction;
b) The "range" and "object" together as a chapter;
c) increase the "Normative References" chapter;
d) Certain editorial changes.
This standard is proposed and managed by the National Electrical Safety Standardization Technical Committee (SAC/TC25).
This standard is drafted by. Institute of Electrical Machinery Industry Beijing Economic and Technology.
The unit participated in the drafting of this standard. Institute of Science in mechanical machine Productivity Promotion Center, Shanghai Electrical Apparatus Research Institute (Group) Co.
The company, Shanghai Electric Tool Research Institute, the Guangzhou Daily electrical detection, Beijing breakthrough Electric Co., Ltd., Delixi Group Co., Ltd.
The main drafters. Guo Ting, Fang Xiaoyan, Yu Ji Hui, Liu Gonggui, Liu Jiang, Zeng Yan Hong, Jin Weidong, Zhang Yong.
This standard was first published in 1984 and revised in 1993 for the first time, this is the second revision.
GB 4208-2008/IEC 60529.2001
introduction
This standard describes the degree of protection provided by the grading system the electrical device housing. Although this system is suitable for most types of electrical
Equipment, but for specific types of electrical equipment, it does not necessarily apply to all level of protection. It should recommend the device manufacturer to determine the applicable anti
Protection level, and the components of the applications level.
The application of the grading system described embodiment the housing so as to provide complete protection level and give different levels of Test Method system
one. This will enable test equipment for a wider range of products, it will also reduce the number of required test equipment.
The second edition of IEC 60529 takes into account the experience of the first edition, to clarify the requirements. When in fact, prevent human access to hazardous parts grade
When the level is higher than the first characteristic of the digital representation, the present standard by adding the letters A, B, C, D provide a selectable extended range.
In general, according to the previous version of an IP code label housing, the predetermined level for the same edition.
GB 4208-2008/IEC 60529.2001
Shell protection (IP code)
1 Scope and purpose
This standard applies to the rated voltage of not more than 72.5kV, by classifying protective enclosure for electrical equipment protection.
Purpose of this standard is as follows.
a) a predetermined content enclosure class following electrical equipment.
1) close to the shell body to prevent hazardous parts;
2) preventing a solid foreign matter into the apparatus housing;
3) to prevent water from entering the housing of the device causing harmful effects.
b) identifying the degree of protection.
c) for each required degree of protection.
d) according to the requirements of the standard housing for the verification test.
Various products referenced extent and manner of the enclosure class, and what the shell is made, the decision left to the product standards, protection of specific
Test levels used should comply with the provisions of this standard, if necessary, increase the additional requirements in the relevant product standard. Available in the relevant product standard
Registration rules as specified in Appendix B.
Special type of equipment, product standards may specify different requirements, but at least to ensure the same level of safety.
This standard is only considered in all respects comply with the provisions of the relevant product standard housing, under normal conditions of use, housing materials and processes should
Guarantee the achievement of the required level of protection.
If the class of devices to meet the general requirements and test the selected level of protection applies to the device type, the standard is also applicable to the present
Empty enclosure type device.
For mechanical damage, corrosion, corrosive solvents (such as cutting fluid), fungi, insects, solar radiation, freezing, moisture (e.g., due to condensation), burst
Effects of external environmental conditions or other gas bomb shell of the housing apparatus and protective measures and to prevent damage to the outer housing hazardous moving parts
...
View full details