GB 19577-2015: Minimum allowable values of energy efficiency and energy efficiency grades for water chillers

This standard specifies the water chillers energy efficiency allowable values, energy efficiency grades, energy conservation evaluation values, test methods, inspection rules, and energy efficiency grade marking.
GB 19577-2015
GB
NATIONAL STANDARD OF THE
PEOPLE REPUBLIC OF CHINA
ICS 27.010
F 01
Replacing GB 19577-2004
Minimum allowable values of energy efficiency
and energy efficiency grades for water chillers
ISSUED ON. DECEMBER 10, 2015
IMPLEMENTED ON. JANUARY 1, 2017
Issued by. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China (GAQSIQ);
Standardization Administration of China (SAC).
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 5
4 Technical requirements ... 6
5 Test methods ... 7
6 Inspection rules ... 8
7 Marking of energy efficiency grades ... 8
Foreword
Clause 4.3 of this standard is mandatory; the rest are recommended.
This standard was drafted according to the rules given in GB/T 1.1-2009. This standard replaces GB 19577-2004 "The minimum allowable values of the energy efficiency and energy efficiency grades for water chillers". Compared with GB 19577-2004, the main technical changes of this standard are as follows. a) for product?€?s energy efficiency, the allowable values are modified (see 4.2); b) for product energy efficiency grade, the judgment indicators are revised; it is changed FROM COP evaluation TO COP and IPLV evaluation (see Table 1 and Table 2);
c) for product energy efficiency grade, the indicator?€?s specified values are modified (see 4.3).
This standard was proposed by Resource Conservation and Environmental Protection Division of National Development and Reform Commission AND Energy Saving and Comprehensive Utilization Division of Ministry of Industry and Information Technology. This standard shall be under the jurisdiction of National Energy and Management Standardization Technical Committee (SAC / TC20).
Drafting organizations of this standard. China Standardization Academy, Hefei General Machinery Research Institute, Trane Air Conditioning Systems (China) Co., Ltd., Zhuhai Grid Electrical Appliances Co., Ltd., Shanghai Yileng Air Conditioning Equipment Co., Ltd., Shenzhen McQuay Air Conditioning Co., Ltd., Chongqing Midea General System Cold Equipment Co., Ltd., Qingdao Haier Air Conditioner Co. Ltd., Matsushita Compressor (Dalian) Co., Ltd., McQuay Air Conditioning and Refrigeration (Wuhan) Ltd., Hefei General Machinery Products Inspection Institute Co., Johnson Controls Building Equipment Co., Ltd., Zhejiang Dunan Artificial Environment Co., Ltd., Guangdong Jeroen Air Conditioning Co., Ltd., Kunshan Taijia Electrical Co., Ltd., Guangdong Shenling Air Conditioning Equipment Co., Emerson Climate Optimization Technology (Suzhou) Co., Ltd., Guangdong OAK Air Conditioning and Refrigeration Co., Ltd.
The main drafters of this standard. Cheng Jianhong, Zhang Sheng, Zhang Xiuping, Zhong Yu, Zhang Vega, Li Hongbo, Sun Guoping, Ru Zhipeng, Guo Defang, Pan Zudong, Zhou Yingtao, Pan LikKui, Hu Xianghua, Zhuo Peijun, Liu Qiang, Yang Zhangwu, Wu Jiesheng, Pan ZhanhHua, Chen Jun.
Minimum allowable values of energy efficiency and
energy efficiency grades for water chillers
1 Scope
This standard specifies the water chillers?€? energy efficiency allowable values, energy efficiency grades, energy conservation evaluation values, test methods, inspection rules, and energy efficiency grade marking.
This standard applies to the water chillers (heat pump) using the vapour compression cycle, of which the compressor is driven by motor.
2 Normative??references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 10870 The methods of performance test for water cooling (heat pump) packages using the vapour compression cycle
GB/T 18430.1 Water cooling (heat pump) packages using the vapor compression cycle - Part 1. Water cooling (heat pump) packages for industrial & commercial and similar application
GB/T 18430.2 Water cooling (heat pump) packages using the vapor compression cycle - Part 2. Water cooling (heat pump) packages for household and similar application
GB 25131 Safety requirements for water chillers (heat pump) using the vapor compression cycle
3 Terms??and??definitions
The terms and definitions defined in GB/T 18430.1 and GB/T 18430.2 AND the following terms and definitions are applicable to this document.
3.1
GB/T 10870.
6 Inspection??rules
In a batch of products, extract a sample; test the coefficient of performance and integrated part load value. If it does not meet the requirements of 4.2 and 4.3, then extract another two samples. The actual measured values shall all meet the requirements of 4.2 and 4.3; otherwise, this batch of products is determined as unqualified.
For a single product, test its coefficient of performance and integrated part load value. If it does not meet the requirements of 4.2 and 4.3, then it is determined as unqualified.
7 Marking??of??energy??efficiency??grades
7.1 The manufacturers shall base on the requirements of this standard and the test results to determine the chillers?€? rated energy efficiency grade.
7.2 The manufacturers shall, in the documents of the products, indicate the rated energy efficiency grade of the water chillers AND the executed standard number.