Skip to product information
1 of 6

www.ChineseStandard.us -- Field Test Asia Pte. Ltd.

GA 211-2009 English PDF

GA 211-2009 English PDF

Regular price $160.00
Regular price Sale price $160.00
Sale Sold out
Shipping calculated at checkout.

GA 211-2009: High temperature-resistant test methods for smoke and heat exhaust ventilators

Delivery: 9 seconds. Download (and Email) true-PDF + Invoice.
Get Quotation: Click GA 211-2009 (Self-service in 1-minute)
Newer / historical versions: GA 211-2009

Preview True-PDF


Scope

This standard specifies the test device, the ventilator installation, the test method, the
judgement criteria, the test report, etc., of the axial-flow (corresponding centrifugal)
smoke and heat exhaust ventilator, which has a machine number of not more than No.18,
during the high temperature-resistant test in laboratory. For the axial-flow
(corresponding centrifugal) smoke and heat exhaust ventilator, which has a machine
number of more than No.18 AND is equipped with electric heating test device, it is only
subject to the high temperature-resistant test; it does not measure the aerodynamic
performance at high temperature, BUT only measures the aerodynamic performance of
the ventilator at room temperature.
This standard is applicable to the high temperature-resistant performance test of smoke
and heat exhaust ventilator, which is installed in industrial and civil buildings, civil air
defense projects and other buildings, tunnels, subways.

Basic Data

Standard ID GA 211-2009 (GA211-2009)
Description (Translated English) High temperature-resistant test methods for smoke and heat exhaust ventilators
Sector / Industry Public Security (Police) Industry Standard
Classification of Chinese Standard C82
Classification of International Standard 13.220.20
Word Count Estimation 10,120
Date of Issue 2009-02-27
Date of Implementation 2009-03-01
Older Standard (superseded by this standard) GA 211-1999
Quoted Standard GB/T 1236-2000; JB/T 8689-1998
Regulation (derived from) Industry standard filing notice 2010 No. 2 (total 122)
Issuing agency(ies) Ministry of Public Security
Summary This standard specifies the test device, fan installation, test method, judgment criteria and test report of the axial flow type (and corresponding centrifugal type) fire extinguishing blower with the machine number no more than No.18 in the laboratory for high temperature test. (With the corresponding centrifugal) fire exhaust fan using electric heating test device only for high temperature test, despite the high-temperature state of aerodynamic performance, only the fan at room temperature to measure the air Dynamic performance. This standard applies to industrial and civil buildings, civil air defense projects and other buildings, tunnels, subway installed in the fire exhaust fan high temperature performance test.


View full details