{"product_id":"gbt5013-4-2008","title":"GB\/T 5013.4-2008 English PDF (GB\/T5013.4-2008)","description":"\u003ch1\u003eGB\/T 5013.4-2008: Rubber insulated cables of rated voltages up to and including 450\/750V -- Part 4: Cords and flexible cables\u003c\/h1\u003e\u003cb style=\"font-size:16px;\"\u003eDelivery:\u003c\/b\u003e 9 seconds. Download (and Email) true-PDF + Invoice.\u003cbr\u003e\u003cb style=\"font-size:16px;\"\u003eGet Quotation:\u003c\/b\u003e Click \u003ca style=\"color: blue;\" href=\"https:\/\/www.chinesestandard.net\/Cart\/Cart.aspx?GB\/T%205013.4-2008_English\" rel=\"nofollow\"\u003eGB\/T 5013.4-2008\u003c\/a\u003e (Self-service in 1-minute)\u003cbr\u003e\u003cb style=\"font-size:16px;\"\u003eNewer \/ historical versions: \u003c\/b\u003e \u003ca style=\"color: blue;\" href=\"https:\/\/www.chinesestandard.net\/PDF.aspx\/GBT5013.4-2008\"\u003eGB\/T 5013.4-2008\u003c\/a\u003e\u003ch2\u003ePreview True-PDF\u003c\/h2\u003e\u003ciframe src=\"https:\/\/www.chinesestandard.net\/Preview_PDF.aspx\/GBT5013.4-2008\" width=\"445\" height=\"600\" title=\"GB\/T 5013.4-2008 True-PDF\"\u003e\u003c\/iframe\u003e \u003cbr\u003e\u003ch2\u003eScope\u003c\/h2\u003e1.1 Scope \u003cbr\u003eThis Part of GB\/T 5013 details the particular specifications for rubber insulated and braided \u003cbr\u003ecords and for rubber insulated and rubber or polychloroprene or other equivalent synthetic \u003cbr\u003eelastomer sheathed cords and flexible cables of rated voltages up to and including 450\/750 V. \u003cbr\u003eAll cables shall comply with the appropriate requirements given in GB\/T 5013.1 and the \u003cbr\u003eindividual types of cables shall each comply with the particular requirements of this Part. \u003cbr\u003e1.2 Normative References \u003cbr\u003eThe clauses in the following documents, through reference in this Part of GB\/T 5013, become \u003cbr\u003eclauses of this Part. For dated references, subsequent amendments to, or revisions of, any of \u003cbr\u003ethese publications do not apply; however, parties to agreements based on this Part are \u003cbr\u003eencouraged to investigate the possibility of applying the most recent editions of the documents \u003cbr\u003eindicated below. For undated references, the latest edition of the referenced document applies. \u003cbr\u003eGB\/T 2951.1-1997 Common Test Methods for Insulating and Sheathing Materials of Electric \u003cbr\u003eCables - Part 1.Methods for General Application - Section 1.Measurement of Thickness and \u003cbr\u003eOverall Dimensions - Tests for Determining the Mechanical Properties (idt IEC 60811-1-1.1993) \u003cbr\u003eGB\/T 2951.2-1997 Common Test Methods for Insulating and Sheathing Materials of Electric \u003cbr\u003eCables - Part 1.Methods for General Application - Section 2.Thermal Ageing Methods (idt \u003cbr\u003eIEC 60811-1-2.1985) \u003cbr\u003eGB\/T 2951.4-1997 Common Test Methods for Insulating and Sheathing Materials of Electric \u003cbr\u003eCables - Part 1.Methods for General Application - Section 4.Tests at Low Temperature (idt \u003cbr\u003eIEC 60811-1-2.1985) [TRANSLATOR NOTE. it should be IEC 60811-1-4.1985] \u003cbr\u003eGB\/T 2951.5-1997 Common Test Methods for Insulating and Sheathing Materials of Electric \u003cbr\u003eCables - Part 2.Methods Specific to Elastomeric Compounds - Section 1.Ozone Resistance \u003cbr\u003eTest - Hot Set Test - Mineral Oil Immersion Test (idt IEC 60811-2-1.1986) \u003cbr\u003eGB\/T 3956 Conductors of Insulated Cables (GB\/T 3956-1997, idt IEC 60228.1978) \u003cbr\u003eGB\/T 5013.1-2008 Rubber Insulated Vables - Rated Voltages up to and Including 450\/750 V - \u003cbr\u003ePart 1.General Requirements (IEC 60245-1.2003, IDT) \u003cbr\u003eGB\/T 5013.2-2008 Rubber Insulated Cables - Rated Voltages up to and Including 450\/750 V - \u003cbr\u003e\u003cbr\u003e\u003ch2\u003eBasic Data\u003c\/h2\u003e\u003ctable id=\"TableTabAbout0\" rules=\"all\" border=\"1\" style=\"font-family:Arial;font-size:Small;\"\u003e  \u003ctr id=\"TableTabRow10\"\u003e     \u003ctd id=\"TableTabCell110\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eStandard ID\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell120\" align=\"center\"\u003e GB\/T 5013.4-2008 (GB\/T5013.4-2008)\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow20\"\u003e     \u003ctd id=\"TableTabCell210\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eDescription (Translated English)\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell220\" align=\"center\"\u003e Rubber insulated cables of rated voltages up to and including 450\/750V -- Part 4: Cords and flexible cables\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow30\"\u003e     \u003ctd id=\"TableTabCell310\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eSector \/ Industry\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell320\" align=\"center\"\u003e National Standard (Recommended)\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow40\"\u003e     \u003ctd id=\"TableTabCell410\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eClassification of Chinese Standard\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell420\" align=\"center\"\u003e K13\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow50\"\u003e     \u003ctd id=\"TableTabCell510\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eClassification of International Standard\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell520\" align=\"center\"\u003e 29.060.20\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow60\"\u003e     \u003ctd id=\"TableTabCell610\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eWord Count Estimation\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell620\" align=\"center\"\u003e 14,126\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow70\"\u003e     \u003ctd id=\"TableTabCell710\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eDate of Issue\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell720\" align=\"center\"\u003e 2008-01-22\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow80\"\u003e     \u003ctd id=\"TableTabCell810\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eDate of Implementation\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell820\" align=\"center\"\u003e 2008-09-01\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow90\"\u003e     \u003ctd id=\"TableTabCell910\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eOlder Standard (superseded by this standard)\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell920\" align=\"center\"\u003e GB 5013.4-1997\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow100\"\u003e     \u003ctd id=\"TableTabCell1010\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eQuoted Standard\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell1020\" align=\"center\"\u003e GB\/T 2951.1-1997; GB\/T 2951.2-1997; GB\/T 2951.4-1997; GB\/T 2951.5-1997; GB\/T 3956; GB\/T 5013.1-2008; GB\/T 5013.2-2008; GB\/T 5013.8-2006\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow110\"\u003e     \u003ctd id=\"TableTabCell1110\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eAdopted Standard\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell1120\" align=\"center\"\u003e IEC 60245-4-2004, IDT\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow120\"\u003e     \u003ctd id=\"TableTabCell1210\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eRegulation (derived from)\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell1220\" align=\"center\"\u003e Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall)\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow130\"\u003e     \u003ctd id=\"TableTabCell1310\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eIssuing agency(ies)\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell1320\" align=\"center\"\u003e General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China\u003c\/td\u003e  \u003c\/tr\u003e\n\u003ctr id=\"TableTabRow140\"\u003e     \u003ctd id=\"TableTabCell1410\" align=\"center\" font=\"bold\"\u003e \u003cb\u003eSummary\u003c\/b\u003e \u003c\/td\u003e    \u003ctd id=\"TableTabCell1420\" align=\"center\"\u003e This standard specifies the rated voltage 450\/750V rubber insulated rubber or neoprene or other equivalent synthetic elastomer sheathed cords and flexible cables technical requirements. Each cable shall comply with GB\/T 5013. 1 requirements, and each type cables shall each comply with the special requirements of this section. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e","brand":"www.ChineseStandard.us -- Field Test Asia Pte. Ltd.","offers":[{"title":"Default Title","offer_id":53136800284986,"sku":null,"price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0821\/5737\/1706\/files\/GBT5013.4-2008EN.1_5d9fbf06-b3fb-46bd-84f4-4af72ee03b6c.jpg?v=1773109127","url":"https:\/\/www.chinesestandard.us\/products\/gbt5013-4-2008","provider":"www.ChineseStandard.us (www.ChineseStandard.net)","version":"1.0","type":"link"}