GB/T 24533-2019: Graphite negative electrode materials for lithium ion battery
GB/T 24533-2019
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.050
Q 51
Replacing GB/T 24533-2009
Graphite negative electrode materials for lithium ion
battery
ISSUED ON: MARCH 25, 2019
IMPLEMENTED ON: FEBRUARY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of PRC.
Table of Contents
Foreword ... 4
1 Scope ... 8
2 Normative references ... 8
3 Terms and definitions ... 9
4 Classification and code ... 9
5 Technical requirements ... 11
6 Test methods ... 11
7 Inspection rules ... 13
8 Packaging, marking ... 14
9 Storage and transportation ... 15
Appendix A (Normative) Method for determination of particle size distribution
... 21
Appendix B (Normative) Method for determination of moisture content ... 25
Appendix C (Normative) Method for determination of pH ... 28
Appendix D (Normative) Method for determination of true density ... 30
Appendix E (Normative) Method for determination of interlayer spacing d002
... 33
Appendix F (Normative) Method for determination of graphite orientation ... 35
Appendix G (Normative) Method for determination of first coulomb efficiency
and first discharge specific capacity ... 38
Appendix H (Normative) Method for determination of trace metal elements .. 42
Appendix I (Normative) Method for determination of anions ... 45
Appendix J (Normative) Method for determination of sulfur content ... 49
Appendix K (Normative) Method for determination of magnetic substances .. 52
Appendix L (Normative) Method for determination of powder compaction
density ... 56
Appendix M (Normative) Method for determination of tap density ... 58
Graphite negative electrode materials for lithium ion
battery
1 Scope
This standard specifies the terms and definitions, classification and code,
technical requirements, test methods and inspection rules for graphite negative
electrode materials for lithium ion battery.
This standard applies to graphite-based negative electrode materials used as
negative electrodes for lithium ion batteries.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 1427 Sampling method for carbon material
GB/T 3120 Nickel wire
GB/T 3521 Method for chemical analysis of graphite
GB/T 3782 Acetylene black
GB/T 4369 Lithium
GB/T 5187 Foil of copper and copper alloy
GB/T 6388 Sign for transport packaging receipt and delivery
GB/T 6682 Water for analytical laboratory use - Specification and test
methods
GB/T 8170 Rules of rounding off for numerical values and expression and
judgement of limiting values
GB/T 9724 Chemical reagent - General rule for the determination of pH
- When the production equipment is shut down for more than half a year and
production is started again;
- When the customer has special requirements.
7.3 Acceptance rules
7.3.1 The product complies with all the technical indicators in Table 1, Table 3,
Table 4 and Table 5 as qualified products. If one of the indicators does not meet
the requirements of this standard, it shall be doubled from the sampling bag of
the same batch of products for re-inspection of the unqualified items. If all the
re-inspections are qualified, it is qualified; if one item fails, it is unqualified.
7.3.2 The manufacturer shall ensure that the exit-factory products meet the
requirements as stipulated in this standard. Each batch of products shall be
accompanied by an inspection report when exit-factory.
7.3.3 The re-inspection period of the consignee shall be two months. If there is
any objection, it shall be double-sampled and re-inspected. If there is still
dispute, it shall be inspected by a qualified third-party testing agency.
8 Packaging, marking
8.1 The packaging and marking of the product shall comply with the provisions
of GB/T 191. The net weight shall be negotiated between the supplier and the
purchaser.
8.2 The packaging shall be carried out under dry conditions. The product is first
placed into a waterproof packaging bag (PE sealed bag, aluminum plastic
sealed bag is recommended). Special packaging requirements are agreed
upon by the supplier and the purchaser.
8.3 The packaged product is then packaged by the outer packaging material,
which is agreed by the supplier and the purchaser.
8.4 The marking shall comply with the provisions of GB/T 6388, and generally
shall include the following contents, or may be marked according to customer
needs:
- Product name;
- Product code and specifications;
- This standard number;
- Net weight;
Appendix B
(Normative)
Method for determination of moisture content
B.1 Scope
This Appendix applies to the Karl Fischer Coulometric titrator to measure the
moisture content of the specimen.
B.2 Principle
The following reactions occur in the presence of water, iodine and sulfur dioxide
in the presence of organic bases and methanol:
H2O + I2 + SO2 + CH3OH + 3RN → [RHN]SO4CH3 + 2[RHN]I
The iodine therein is produced by electrochemically oxidizing the electrolytic
cell.
2I- → I2 + 2e-
The amount of iodine produced is proportional to the electric quantity passing
through the electrolytic cell, so the electric quantity consumed by electrolysis is
recorded, and according to Faraday's law, the moisture content of the specimen
(10.72 mC ≈ 1 µg H2O) can be obtained. Moisture content is expressed as a
percentage:
Water [%] = {(consumption [mC] ÷ 10.72 [mC/μg] - (drift [μg/min] × duration
[min]) - blank value [μg]) × 100 [%]} / {mass [g] × 106[mg/g]}
In order to obtain the moisture content expressed in ppm, it may be multiplied
by 10000. In order to obtain the moisture content expressed in grams/kilograms
(g/kg), it may be multiplied by 10.
B.3 Reagents and materials
B.3.1 Desiccant: 3A molecular sieve.
B.3.2 Electrolyte: Diaphragm-free electrolyte (commodity: shelf life, 5 years;
storage conditions: moisture-proof sealed).
B.4 Instruments and equipment
B.4.1 Karl Fischer coulometric titrator: The measurement range is 0.0001% ~
1%.
Appendix C
(Normative)
Method for determination of pH
C.1 Scope
This Appendix applies to the use of pH meter to test the pH value of the graphite
negative electrode materials.
C.2 Principle
Mix the specimen and the distilled water. Use pH meter to determine the pH
value of the specimen.
C.3 Reagents and materials
C.3.1 Pure water (GB/T 6682), grade-III.
Before use, put it in a chemically resistant glass container and boil for 5 min ~
10 min. Cover it to cool to room temperature. Let it be standing for not more
than 30 min.
C.3.2 In the analysis, unless otherwise specified, analytically pure or superior
grade reagents are used. The bagged pH standard substance with certificate
may be used according to the instruction manual. It may also be prepared
according to the provisions of GB/T 9724.
C.4 Instruments and equipment
C.4.1 Analytical balance: Sensitivity 0.0001 g.
C.4.2 pH meter: measuring range, 0 ~ 14, accuracy 0.02.
C.4.3 Glass beaker: 100 mL.
C.4.4 Ultrasonic cleaning instrument: Ultrasonic po...
Get QUOTATION in 1-minute: Click GB/T 24533-2019
Historical versions: GB/T 24533-2019
Preview True-PDF (Reload/Scroll if blank)
GB/T 24533-2019: Graphite negative electrode materials for lithium ion battery
GB/T 24533-2019
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 29.050
Q 51
Replacing GB/T 24533-2009
Graphite negative electrode materials for lithium ion
battery
ISSUED ON: MARCH 25, 2019
IMPLEMENTED ON: FEBRUARY 01, 2020
Issued by: State Administration for Market Regulation;
Standardization Administration of PRC.
Table of Contents
Foreword ... 4
1 Scope ... 8
2 Normative references ... 8
3 Terms and definitions ... 9
4 Classification and code ... 9
5 Technical requirements ... 11
6 Test methods ... 11
7 Inspection rules ... 13
8 Packaging, marking ... 14
9 Storage and transportation ... 15
Appendix A (Normative) Method for determination of particle size distribution
... 21
Appendix B (Normative) Method for determination of moisture content ... 25
Appendix C (Normative) Method for determination of pH ... 28
Appendix D (Normative) Method for determination of true density ... 30
Appendix E (Normative) Method for determination of interlayer spacing d002
... 33
Appendix F (Normative) Method for determination of graphite orientation ... 35
Appendix G (Normative) Method for determination of first coulomb efficiency
and first discharge specific capacity ... 38
Appendix H (Normative) Method for determination of trace metal elements .. 42
Appendix I (Normative) Method for determination of anions ... 45
Appendix J (Normative) Method for determination of sulfur content ... 49
Appendix K (Normative) Method for determination of magnetic substances .. 52
Appendix L (Normative) Method for determination of powder compaction
density ... 56
Appendix M (Normative) Method for determination of tap density ... 58
Graphite negative electrode materials for lithium ion
battery
1 Scope
This standard specifies the terms and definitions, classification and code,
technical requirements, test methods and inspection rules for graphite negative
electrode materials for lithium ion battery.
This standard applies to graphite-based negative electrode materials used as
negative electrodes for lithium ion batteries.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 1427 Sampling method for carbon material
GB/T 3120 Nickel wire
GB/T 3521 Method for chemical analysis of graphite
GB/T 3782 Acetylene black
GB/T 4369 Lithium
GB/T 5187 Foil of copper and copper alloy
GB/T 6388 Sign for transport packaging receipt and delivery
GB/T 6682 Water for analytical laboratory use - Specification and test
methods
GB/T 8170 Rules of rounding off for numerical values and expression and
judgement of limiting values
GB/T 9724 Chemical reagent - General rule for the determination of pH
- When the production equipment is shut down for more than half a year and
production is started again;
- When the customer has special requirements.
7.3 Acceptance rules
7.3.1 The product complies with all the technical indicators in Table 1, Table 3,
Table 4 and Table 5 as qualified products. If one of the indicators does not meet
the requirements of this standard, it shall be doubled from the sampling bag of
the same batch of products for re-inspection of the unqualified items. If all the
re-inspections are qualified, it is qualified; if one item fails, it is unqualified.
7.3.2 The manufacturer shall ensure that the exit-factory products meet the
requirements as stipulated in this standard. Each batch of products shall be
accompanied by an inspection report when exit-factory.
7.3.3 The re-inspection period of the consignee shall be two months. If there is
any objection, it shall be double-sampled and re-inspected. If there is still
dispute, it shall be inspected by a qualified third-party testing agency.
8 Packaging, marking
8.1 The packaging and marking of the product shall comply with the provisions
of GB/T 191. The net weight shall be negotiated between the supplier and the
purchaser.
8.2 The packaging shall be carried out under dry conditions. The product is first
placed into a waterproof packaging bag (PE sealed bag, aluminum plastic
sealed bag is recommended). Special packaging requirements are agreed
upon by the supplier and the purchaser.
8.3 The packaged product is then packaged by the outer packaging material,
which is agreed by the supplier and the purchaser.
8.4 The marking shall comply with the provisions of GB/T 6388, and generally
shall include the following contents, or may be marked according to customer
needs:
- Product name;
- Product code and specifications;
- This standard number;
- Net weight;
Appendix B
(Normative)
Method for determination of moisture content
B.1 Scope
This Appendix applies to the Karl Fischer Coulometric titrator to measure the
moisture content of the specimen.
B.2 Principle
The following reactions occur in the presence of water, iodine and sulfur dioxide
in the presence of organic bases and methanol:
H2O + I2 + SO2 + CH3OH + 3RN → [RHN]SO4CH3 + 2[RHN]I
The iodine therein is produced by electrochemically oxidizing the electrolytic
cell.
2I- → I2 + 2e-
The amount of iodine produced is proportional to the electric quantity passing
through the electrolytic cell, so the electric quantity consumed by electrolysis is
recorded, and according to Faraday's law, the moisture content of the specimen
(10.72 mC ≈ 1 µg H2O) can be obtained. Moisture content is expressed as a
percentage:
Water [%] = {(consumption [mC] ÷ 10.72 [mC/μg] - (drift [μg/min] × duration
[min]) - blank value [μg]) × 100 [%]} / {mass [g] × 106[mg/g]}
In order to obtain the moisture content expressed in ppm, it may be multiplied
by 10000. In order to obtain the moisture content expressed in grams/kilograms
(g/kg), it may be multiplied by 10.
B.3 Reagents and materials
B.3.1 Desiccant: 3A molecular sieve.
B.3.2 Electrolyte: Diaphragm-free electrolyte (commodity: shelf life, 5 years;
storage conditions: moisture-proof sealed).
B.4 Instruments and equipment
B.4.1 Karl Fischer coulometric titrator: The measurement range is 0.0001% ~
1%.
Appendix C
(Normative)
Method for determination of pH
C.1 Scope
This Appendix applies to the use of pH meter to test the pH value of the graphite
negative electrode materials.
C.2 Principle
Mix the specimen and the distilled water. Use pH meter to determine the pH
value of the specimen.
C.3 Reagents and materials
C.3.1 Pure water (GB/T 6682), grade-III.
Before use, put it in a chemically resistant glass container and boil for 5 min ~
10 min. Cover it to cool to room temperature. Let it be standing for not more
than 30 min.
C.3.2 In the analysis, unless otherwise specified, analytically pure or superior
grade reagents are used. The bagged pH standard substance with certificate
may be used according to the instruction manual. It may also be prepared
according to the provisions of GB/T 9724.
C.4 Instruments and equipment
C.4.1 Analytical balance: Sensitivity 0.0001 g.
C.4.2 pH meter: measuring range, 0 ~ 14, accuracy 0.02.
C.4.3 Glass beaker: 100 mL.
C.4.4 Ultrasonic cleaning instrument: Ultrasonic po...