1
/
su
7
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
GB/T 18268.1-2010 English PDF (GBT18268.1-2010)
GB/T 18268.1-2010 English PDF (GBT18268.1-2010)
Prezzo di listino
$115.00 USD
Prezzo di listino
Prezzo scontato
$115.00 USD
Prezzo unitario
/
per
Spese di spedizione calcolate al check-out.
Impossibile caricare la disponibilità di ritiro
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB/T 18268.1-2010
Historical versions: GB/T 18268.1-2010
Preview True-PDF (Reload/Scroll if blank)
GB/T 18268.1-2010: Electrical equipment for measurement, control and laboratory use -- EMC requirements -- Part 1: General requirements
GB/T 18268.1-2010
Electrical equipment for measurement, control and laboratory use EMC requirements Part 1. General requirements
ICS 25.040.40; 33.100
N10
National Standards of People's Republic of China
Replacing GB/T 18268-2000
Electrical equipment for measurement, control and laboratory use
Electromagnetic compatibility requirements
Part 1. General requirements
Electricalequipmentformeasurement, controlandlaboratoryuse-
EMCrequirements-Part 1. Generalrequirements
(IEC 61326-1.2005, IDT)
Issued on. 2011-01-14
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 18268 "for measurement, control and laboratory use EMC requirements for electrical equipment" series of standards includes the following components.
--- Part 1. General requirements;
--- PART 21. Particular requirements for electromagnetic compatible test configuration with a protective case sensitivity test and measurement equipment, working conditions
And performance criteria;
--- Part 22. Particular requirements for low-voltage distribution systems with a portable test, measuring and monitoring equipment test configuration, working conditions and
Performance criteria;
--- Part 23. Particular requirements for integrated or remote signal conditioning transmitter test configuration, operating conditions and performance criteria;
--- Part 24. Particular requirements for compliance with IEC 61557-8 insulation monitoring device and comply with IEC 61557-9 insulation faults fixed
Test configuration bits of equipment, working conditions and performance criteria;
--- Part 25. Particular requirements for interface conforms to IEC 61784-1, the test configuration of field devices CP3/2, working conditions and sexual
Energy criterion;
--- Part 26. Particular requirements for in vitro diagnostic (IVD) medical equipment;
--- Part 31. execution or ready to perform safety functions (functional safety) equipment immunity requirements for general industrial applications;
--- Part 32. perform or ready to perform safety functions (functional safety) equipment immunity requirements specified electromagnetic environment
Industrial applications.
This part of GB/T 18268 Part 1.
This section identical with the international standard IEC 61326-1.2005 (first edition) "Electrical equipment for measurement, control and laboratory use compatible
Requirements - Part 1. General requirements "(in English).
This section is equivalent translation IEC 61326-1.2005.
This section based on GB/T 1.1-2000 "Standardization Guide Part 1. Standard structure and writing rules" and
GB/T 20000.2-2001. the relevant provisions of "Standardization Guide Part 2 rules of international standards," the editorial the following
modify.
--- Remove the foreword and introduction of international standards;
--- "IEC 61326 this part" to "GB/T 18268 in this section";
--- Original language reference guide documents according to the provisions of GB/T 1.1-2000 changed to normative documents referenced introductory phrase;
--- With a decimal point "." Instead of a comma as the decimal point "."
The partial substitution of GB/T 18268-2000 "measurement, control and laboratory use electrical equipment electromagnetic compatibility requirements."
This section compared with the GB/T 18268-2000, technical content amended as follows.
--- Part 2 normative references added IEC 61000-6-1, IEC 61000-3-11, IEC 61000-3-12; deleted
The GB/T 2900.1, GB 4793.1, GB 4343, GB/T 6113.1, GB/T 6113.2, GB 9254.
--- Part 3 Terms and definitions added "functional ground."
--- This section 5.2.2 adds the contents of the software requirements.
--- This section 5.2.4 adds support for electrostatic discharge test method requirements.
--- The revised section 6.2 Table 1, Table 2, Table 3, deleted the conducted immunity test can not be described.
--- This partial deletion of GB/T 18268-2000 7.2 Table 3 and Table 4, the emission limits direct reference to GB 4824,
GB/T 17625.1 (or IEC 61000-3-12), GB 17625.2 (or IEC 61000-3-11).
--- This section adds instructions for use Chapter 9.
--- This partial deletion of GB/T 18268-2000 Appendix A, Appendix B, Appendix A and Appendix B of the content and 6.2.
--- This part of the GB/T 18268-2000 Appendix C to Appendix A, Table A.1 to Table C.1 and modified.
--- This section adds references.
This section of Appendix A normative appendix.
This part is proposed by China Machinery Industry Federation.
This part of the measurement and control of Standardization Technical Committee (SAC/TC124) is administered by the National industrial processes.
This section is responsible for drafting unit. Shanghai Institute of Industrial Automation Instrumentation.
Participated in the drafting of this section. Shanghai Automation Instrumentation System Inspection and Testing Institute, Fujian on the Run Precision Instrument Co., Ltd.
The main drafters of this section. Wang Ying, Hong Ji Ye, Li Minghua, Ge Jian.
This part of the standard replaces the previous editions are.
--- GB/T 18268-2000.
Electrical equipment for measurement, control and laboratory use
Electromagnetic compatibility requirements
Part 1. General requirements
1 Scope
This section GB/T 18268 specifies the electrical equipment for the professional, industrial process, manufacturing and educational use of the electromagnetic compatibility Immunity
Degree and emission requirements, these electronic devices are made smaller than 1000V ac or 1500V dc power supply or battery, or powered by the circuit under test
Work, including equipment and computing devices for industrial and non-industrial sites.
--- Measurement and testing;
---control;
--- Laboratory;
--- Apparatus used in combination with the above auxiliary equipment (such as a sample processing apparatus).
Belonging to IT equipment (referred to ITE) and components of the computing device and similar devices in range, if they meet the appropriate set of IT
Electromagnetic compatibility standard equipment can be used in the GB/T 18268 scope of this part of the system, without the need for additional tests.
This series of product standards take precedence over generic standards.
This section relates to the following devices.
a) measurement and test of electrical equipment
Such devices are those that use electricity to measure, indicate or record one or more battery or power device, including non-measurement devices
Equipment such as signal generators, measurement standards, power and sensors.
b) the control of electrical equipment
Such devices refers to one or more output control device in a predetermined value, each value manually set by local or
Remote program control, or determined by one or more input variables. Such equipment includes industrial process measurement and control equipment, which was made
By means, for instance.
--- Process controllers and regulators;
---Programmable Controllers;
--- Equipment and systems for power supply unit (centralized or dedicated);
--- Analog/digital indicator and recorder;
--- Process instrumentation;
--- Sensors, positioners, intelligent actuators and the like.
c) electrical laboratory equipment
Such equipment is used to measure the mean, instructions, monitor or analyze substances, or for the preparation of equipment, including in vitro diagnostic devices.
Such devices can also be used in other places in addition to the laboratory, such as in vitro diagnostic devices to detect from home.
This section app...
Get QUOTATION in 1-minute: Click GB/T 18268.1-2010
Historical versions: GB/T 18268.1-2010
Preview True-PDF (Reload/Scroll if blank)
GB/T 18268.1-2010: Electrical equipment for measurement, control and laboratory use -- EMC requirements -- Part 1: General requirements
GB/T 18268.1-2010
Electrical equipment for measurement, control and laboratory use EMC requirements Part 1. General requirements
ICS 25.040.40; 33.100
N10
National Standards of People's Republic of China
Replacing GB/T 18268-2000
Electrical equipment for measurement, control and laboratory use
Electromagnetic compatibility requirements
Part 1. General requirements
Electricalequipmentformeasurement, controlandlaboratoryuse-
EMCrequirements-Part 1. Generalrequirements
(IEC 61326-1.2005, IDT)
Issued on. 2011-01-14
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 18268 "for measurement, control and laboratory use EMC requirements for electrical equipment" series of standards includes the following components.
--- Part 1. General requirements;
--- PART 21. Particular requirements for electromagnetic compatible test configuration with a protective case sensitivity test and measurement equipment, working conditions
And performance criteria;
--- Part 22. Particular requirements for low-voltage distribution systems with a portable test, measuring and monitoring equipment test configuration, working conditions and
Performance criteria;
--- Part 23. Particular requirements for integrated or remote signal conditioning transmitter test configuration, operating conditions and performance criteria;
--- Part 24. Particular requirements for compliance with IEC 61557-8 insulation monitoring device and comply with IEC 61557-9 insulation faults fixed
Test configuration bits of equipment, working conditions and performance criteria;
--- Part 25. Particular requirements for interface conforms to IEC 61784-1, the test configuration of field devices CP3/2, working conditions and sexual
Energy criterion;
--- Part 26. Particular requirements for in vitro diagnostic (IVD) medical equipment;
--- Part 31. execution or ready to perform safety functions (functional safety) equipment immunity requirements for general industrial applications;
--- Part 32. perform or ready to perform safety functions (functional safety) equipment immunity requirements specified electromagnetic environment
Industrial applications.
This part of GB/T 18268 Part 1.
This section identical with the international standard IEC 61326-1.2005 (first edition) "Electrical equipment for measurement, control and laboratory use compatible
Requirements - Part 1. General requirements "(in English).
This section is equivalent translation IEC 61326-1.2005.
This section based on GB/T 1.1-2000 "Standardization Guide Part 1. Standard structure and writing rules" and
GB/T 20000.2-2001. the relevant provisions of "Standardization Guide Part 2 rules of international standards," the editorial the following
modify.
--- Remove the foreword and introduction of international standards;
--- "IEC 61326 this part" to "GB/T 18268 in this section";
--- Original language reference guide documents according to the provisions of GB/T 1.1-2000 changed to normative documents referenced introductory phrase;
--- With a decimal point "." Instead of a comma as the decimal point "."
The partial substitution of GB/T 18268-2000 "measurement, control and laboratory use electrical equipment electromagnetic compatibility requirements."
This section compared with the GB/T 18268-2000, technical content amended as follows.
--- Part 2 normative references added IEC 61000-6-1, IEC 61000-3-11, IEC 61000-3-12; deleted
The GB/T 2900.1, GB 4793.1, GB 4343, GB/T 6113.1, GB/T 6113.2, GB 9254.
--- Part 3 Terms and definitions added "functional ground."
--- This section 5.2.2 adds the contents of the software requirements.
--- This section 5.2.4 adds support for electrostatic discharge test method requirements.
--- The revised section 6.2 Table 1, Table 2, Table 3, deleted the conducted immunity test can not be described.
--- This partial deletion of GB/T 18268-2000 7.2 Table 3 and Table 4, the emission limits direct reference to GB 4824,
GB/T 17625.1 (or IEC 61000-3-12), GB 17625.2 (or IEC 61000-3-11).
--- This section adds instructions for use Chapter 9.
--- This partial deletion of GB/T 18268-2000 Appendix A, Appendix B, Appendix A and Appendix B of the content and 6.2.
--- This part of the GB/T 18268-2000 Appendix C to Appendix A, Table A.1 to Table C.1 and modified.
--- This section adds references.
This section of Appendix A normative appendix.
This part is proposed by China Machinery Industry Federation.
This part of the measurement and control of Standardization Technical Committee (SAC/TC124) is administered by the National industrial processes.
This section is responsible for drafting unit. Shanghai Institute of Industrial Automation Instrumentation.
Participated in the drafting of this section. Shanghai Automation Instrumentation System Inspection and Testing Institute, Fujian on the Run Precision Instrument Co., Ltd.
The main drafters of this section. Wang Ying, Hong Ji Ye, Li Minghua, Ge Jian.
This part of the standard replaces the previous editions are.
--- GB/T 18268-2000.
Electrical equipment for measurement, control and laboratory use
Electromagnetic compatibility requirements
Part 1. General requirements
1 Scope
This section GB/T 18268 specifies the electrical equipment for the professional, industrial process, manufacturing and educational use of the electromagnetic compatibility Immunity
Degree and emission requirements, these electronic devices are made smaller than 1000V ac or 1500V dc power supply or battery, or powered by the circuit under test
Work, including equipment and computing devices for industrial and non-industrial sites.
--- Measurement and testing;
---control;
--- Laboratory;
--- Apparatus used in combination with the above auxiliary equipment (such as a sample processing apparatus).
Belonging to IT equipment (referred to ITE) and components of the computing device and similar devices in range, if they meet the appropriate set of IT
Electromagnetic compatibility standard equipment can be used in the GB/T 18268 scope of this part of the system, without the need for additional tests.
This series of product standards take precedence over generic standards.
This section relates to the following devices.
a) measurement and test of electrical equipment
Such devices are those that use electricity to measure, indicate or record one or more battery or power device, including non-measurement devices
Equipment such as signal generators, measurement standards, power and sensors.
b) the control of electrical equipment
Such devices refers to one or more output control device in a predetermined value, each value manually set by local or
Remote program control, or determined by one or more input variables. Such equipment includes industrial process measurement and control equipment, which was made
By means, for instance.
--- Process controllers and regulators;
---Programmable Controllers;
--- Equipment and systems for power supply unit (centralized or dedicated);
--- Analog/digital indicator and recorder;
--- Process instrumentation;
--- Sensors, positioners, intelligent actuators and the like.
c) electrical laboratory equipment
Such equipment is used to measure the mean, instructions, monitor or analyze substances, or for the preparation of equipment, including in vitro diagnostic devices.
Such devices can also be used in other places in addition to the laboratory, such as in vitro diagnostic devices to detect from home.
This section app...
Share