GB/T 16150-1995: Sieve test for dustable and wettable powders of pesticides
GB/T 16150-1995
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 65.100
G 23
Sieve test for dustable and wettable powders of pesticides
ISSUED ON: DECEMBER 21, 1995
IMPLEMENTED ON: AUGUST 01, 1996
Issued by: The State Bureau of Quality and Technical Supervision
Table of Contents
1 Scope ... 3
2 Method ... 3
Additional information: ... 6
Sieve test for dustable and wettable powders of pesticides
1 Scope
This method is applicable to the sieve test for dustable and wettable powders of
pesticides.
2 Method
2.1 Dry sieving method (applicable to powders)
2.1.1 Method summary: Dry the sample in the oven to constant weight and cool it
naturally to room temperature. After the sample and the atmosphere reach humidity
equilibrium, weigh a specimen. Sieve to the end point with a test sieve of appropriate
hole size. Weigh the residue in the sieve. Calculate the fineness (if the dried sample is
easy to absorb moisture, the sample must be placed in a desiccator to cool, and the
contact between the sample and the atmospheric environment shall be minimized to
complete the screening).
2.1.2 Instruments
Test sieve: appropriate aperture, with matching receiving plate and cover.
Glass dish: known mass.
Brush: 2.5 cm soft flat brush.
Constant temperature oven: temperature control accuracy within 100°C is ±2°C.
Desiccator.
2.1.3 Determination steps
2.1.3.1 Sample preparation
Adjust the oven to the appropriate temperature according to the characteristics of the
sample. A sufficient amount of sample is dried in the oven to constant weight. The
sample is then naturally cooled to room temperature and equilibrated with atmospheric
humidity for later use.
If the sample absorbs moisture easily, it shall be cooled to room temperature in the
desiccator. And try to minimize contact with the atmospheric environment.
2.1.3.2 Determination
Weigh 20 g of specimen (accurate to 0.1 g). Place in a test sieve of appropriate aperture
that fits the receiving plate. Close the lid. Carry out the test in one of two ways.
a. Vibrating screen method
Install the test sieve on the vibrating screen machine and vibrate, while tapping the left
and right sides of the receiving plate alternately. After 10 min, turn off the vibrating
screen machine. Let the dust settle for a few seconds and then remove the sieve lid. Use
a brush to remove any material blocking the mesh. Also disperse soft clumps in the
sieve, but hard particles shall not be crushed. Cover the screen cover and turn on the
vibrating screen machine. Repeat the above process until less than 0.01 g is sifted within
2 min. Transfer the residue in the sieve to a glass dish and weigh it.
b. Hand screening method
Hold the screen cover and both sides of the receiving plate firmly with both hands. On
the operating table with rubber cover, repeatedly touch the bottom of the left and right
sides of the receiving plate with the operating table to vibrate the screen. Adjust the
screen position clockwise from time to time (or counterclockwise). Allow the dust to
settle for a few seconds before removing the lid. Use a brush to clean away material
blocking the mesh. Also disperse soft clumps, but hard particles shall not be crushed.
Repeat vibrating and sieving until less than 0.01 g is sieved within 2 min. Transfer the
residue in the sieve to a glass dish and weigh it.
2.2 Wet sieving method (applicable to wettable powders)
2.2.1 Method summary
Place the weighed specimen in a beaker, moisten and dilute it. Pour into a moistened
test sieve. Rinse directly with gentle running water. Then place the test sieve in a basin
filled with water and continue washing. Transfer the residue in the sieve to a beaker.
Dry the residue and weigh. Calculate fineness.
2.2.2 Instruments
Test sieve: appropriate aperture, and equipped with matching receiving plate and lid.
Beakers: 250 mL, 100 mL.
Oven: temperature control accuracy within 100°C is ±2°C.
Glass rod: with rubber cover.
Desiccator.
2.2.3 Determination steps
2.2.3.1 Wetting of specimen