1
/
de
10
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
GB/T 11865-2008 English PDF (GBT11865-2008)
GB/T 11865-2008 English PDF (GBT11865-2008)
Prix habituel
$85.00 USD
Prix habituel
Prix promotionnel
$85.00 USD
Prix unitaire
/
par
Frais d'expédition calculés à l'étape de paiement.
Impossible de charger la disponibilité du service de retrait
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB/T 11865-2008
Historical versions: GB/T 11865-2008
Preview True-PDF (Reload/Scroll if blank)
GB/T 11865-2008: Marine centrifugal fans
GB/T 11865-2008
GB
ICS 47.020.50
U 47
National Standard
of the People’s Republic of China
Replacing GB/T 11865-1989, GB/T 11866-1989
Marine centrifugal fans
ISSUED ON. MARCH 3, 2008
IMPLEMENTED ON. SEPTEMBER 1, 2008
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration Committee.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 5
4 Product classifications ... 6
5 Requirements ... 8
6 Test methods ... 12
7 Inspection rules ... 13
8 Marking, packaging, transportation and storage ... 15
Foreword
This Standard replaces GB/T 11865-1989 "Marine centrifugal fans", and GB/T
11866-1989 "Marine centrifugal backward-curved blade fans".
Compared with GB/T 11865-1989 and GB/T 11866-1989, the main technical content
changes are as follows.
— EXPAND the performance parameters table. The flow is expanded to 4 grades -
21 000 m3/h, 27 000 m3/h, 32 000 m3/h, and 40 000 m3/h;
— UNIFY the representing method for fans’ product model;
— DESCRIBE the overall requirements AND fans’ requirements to major parts;
— REFINE the packaging requirements of fans’ products.
The Standard was proposed by China Shipbuilding Industry Corporation.
This Standard shall be under the jurisdiction of the Deck Machinery and Auxiliary
Machinery Sub-Technical Committee of China Marine Machinery Standardization
Technical Committee.
Drafting organization of this Standard. the 704 Institute of China Shipbuilding Industry
Corporation.
Main drafters of this Standard. Qiao Jiang, Ding Kejin, and Zhang Shuo.
The previous versions replaced by this Standard are.
— GB/T 11865-1989, GB/T 11866-1989.
Marine centrifugal fans
1 Scope
This Standard specifies the single-stage, single-suction marine centrifugal fans’
(hereinafter referred to as "fans") product classification, requirements, test methods,
inspection rules, marking, packaging, transportation, and storage.
This Standard applies to the design, production, testing, and acceptance of the fans
used for ventilation.
2 Normative references
The provisions in following documents become the provisions of this Standard through
reference in this Standard. For dated references, the subsequent amendments
(excluding corrections) or revisions do not apply to this Standard, however, parties
who reach an agreement based on this Standard are encouraged to study if the latest
versions of these documents are applicable. For undated references, the latest edition
of the referenced document applies.
GB/T 191 Packaging - Pictorial marking for handling of goods (GB/T 191-2000, eqv
ISO 780.1997)
GB/T 1236 Industrial fans - Performance testing using standardized airways (GB/T
1236-2000, idt ISO 5801.1997)
GB/T 1804-2000 General tolerances - Tolerances for linear and angular
dimensions without individual tolerance indications (eqv ISO 2768-1.1989)
GB/T 2888 Methods of noise measurement for fans blowers compressors and
roots blowers
GB/T 3235 Basic types sizes parameters and characteristics curve of fans
GB/T 8923-1988 Rust grades and preparation grades of steel surfaces before
application of paints and related products (eqv ISO 8501-1.1988)
GB/T 9438 Aluminum alloy castings
GB/T 13306 Plates
GB/T 13384 General specifications for packing of mechanical and electrical
product
GB/T 16301-2008 Measurement and evaluation of vibration severity for marine
engine-room auxiliaries
CB 1146.1-1996 Environmental test and engineering guide of ship equipment -
General principles
CB 1146.6-1996 Environmental test and engineering guide of ship equipment -
Impact
CB 1146.8-1996 Environmental test and engineering guide of ship equipment - Tilt
and swing
CB 1146.9-1996 Environmental test and engineering guide of ship equipment -
Vibration
JB/T 6445 Overspeed test for industrial fan impeller
JB/T 6886 Technical specification for draught fan application
JB/T 9101 Fan rotor balance
JB/T 10214 Specification of riveting and welding part for fans
3 Terms and definitions
3.1
rated condition
The highest point of fans’ theoretical design working efficiency is fans’ rated condition.
That is the work point determined by the pressure and flow at the rated point.
3.2
standard condition of inspiration
The condition in which the atmospheric pressure is 101 325 Pa; the temperature is
20 °C; the relative humidity is 50%; and the air density is 1.2 kg/m3.
3.3
standard condition of flux
The air volume converted from fans’ actual flow, under the standard condition of
inspiration.
coated, but the exposed surfaces shall get treatment such as polishing and
passivation.
5.3.1.3 The steel-parts of fans shall get galvanization treatment. And the galvanization
thickness shall not be less than 0.045mm. Rust grades of steel materials be used
shall not be less than Grade B specified in GB 8923-1988. Spray rust-removal or
projectile rust-removal shall reach Grade Sa3 specified in GB 8923-1988. Manual and
power-tool rust-removal shall reach Grade St3 specified in GB 8923-1988.
5.3.1.4 Fans’ chassis bottom (the lowest point) shall have a drain plug.
5.3.1.5 Fans’ riveting parts and welding parts shall comply with the specifications of
JB/T 10214.
5.3.1.6 Fans can be made into clockwise rotation (right-handed rotation) or
counterclockwise rotation (left-handed rotation).
Counterclockwise (left-handed rotation) - PLACE the electric-motor flatly. VIEW
from the electric-motor. The impeller rotates counterclockwise when running. It is
represented by "L".
Clockwise (right-handed rotation) - PLACE the electric-motor flatly. VIEW from the
electric-motor. The impeller rotates clockwise when running. It is represented by
"R".
5.3.1.7 Fans’ outlet position can be made into the following basic forms (see Figure 2)
according to impeller’s rotating direction. As needed, the outlet is allowed to adopt the
30° variation forms.
Figure 2 Front-view from the electric-motor
5.3.2 Impeller
5.3.2.1 Impeller surface’s shape and position tolerances shall not exceed the
requirements in Table 3.
Right 180°
Right 135°
Right 225°
Right 270°
Right 315°
Right 45°
Right 90°
Right 0°
Left 90°
Left 0°
Left 45°
Left 315°
Left 270°
Left 225°
Left 180°
Left 135°
fog, and oil mist;
b) Temperature of -25°C~ + 50°C;
c) Relative humidity is less than 95%;
d) Impact;
e) Tilt and swing;
f) Vibration.
6 Test methods
6.1 Appearance
OBSERVE the internal and external surfaces of fans, the surface quality of welding
parts, and riveting parts visually. The test results shall meet the requirements of 5.1.
6.2 Dimension and weight
MEASURE the main dimensions and weight of fans. The results shall meet the
requirements of 5.2.
6.3 Impeller static and dynamic balance
PERFORM the static and dynamic balancing calibration of the impellers according to
the test requirements specified in JB/T 9101. The test results shall meet the
requirements of 5.4.1.
6.4 Impeller overspeed
Impellers shall run for at least 10 min at a speed that exceeds 20% of rated rotate
speed. The evaluation of the preparation before test AND the test results after running
shall be conducted according to the specifications of JB/T 6445. The test results shall
meet the...
Get QUOTATION in 1-minute: Click GB/T 11865-2008
Historical versions: GB/T 11865-2008
Preview True-PDF (Reload/Scroll if blank)
GB/T 11865-2008: Marine centrifugal fans
GB/T 11865-2008
GB
ICS 47.020.50
U 47
National Standard
of the People’s Republic of China
Replacing GB/T 11865-1989, GB/T 11866-1989
Marine centrifugal fans
ISSUED ON. MARCH 3, 2008
IMPLEMENTED ON. SEPTEMBER 1, 2008
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of the People's Republic of China;
Standardization Administration Committee.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions ... 5
4 Product classifications ... 6
5 Requirements ... 8
6 Test methods ... 12
7 Inspection rules ... 13
8 Marking, packaging, transportation and storage ... 15
Foreword
This Standard replaces GB/T 11865-1989 "Marine centrifugal fans", and GB/T
11866-1989 "Marine centrifugal backward-curved blade fans".
Compared with GB/T 11865-1989 and GB/T 11866-1989, the main technical content
changes are as follows.
— EXPAND the performance parameters table. The flow is expanded to 4 grades -
21 000 m3/h, 27 000 m3/h, 32 000 m3/h, and 40 000 m3/h;
— UNIFY the representing method for fans’ product model;
— DESCRIBE the overall requirements AND fans’ requirements to major parts;
— REFINE the packaging requirements of fans’ products.
The Standard was proposed by China Shipbuilding Industry Corporation.
This Standard shall be under the jurisdiction of the Deck Machinery and Auxiliary
Machinery Sub-Technical Committee of China Marine Machinery Standardization
Technical Committee.
Drafting organization of this Standard. the 704 Institute of China Shipbuilding Industry
Corporation.
Main drafters of this Standard. Qiao Jiang, Ding Kejin, and Zhang Shuo.
The previous versions replaced by this Standard are.
— GB/T 11865-1989, GB/T 11866-1989.
Marine centrifugal fans
1 Scope
This Standard specifies the single-stage, single-suction marine centrifugal fans’
(hereinafter referred to as "fans") product classification, requirements, test methods,
inspection rules, marking, packaging, transportation, and storage.
This Standard applies to the design, production, testing, and acceptance of the fans
used for ventilation.
2 Normative references
The provisions in following documents become the provisions of this Standard through
reference in this Standard. For dated references, the subsequent amendments
(excluding corrections) or revisions do not apply to this Standard, however, parties
who reach an agreement based on this Standard are encouraged to study if the latest
versions of these documents are applicable. For undated references, the latest edition
of the referenced document applies.
GB/T 191 Packaging - Pictorial marking for handling of goods (GB/T 191-2000, eqv
ISO 780.1997)
GB/T 1236 Industrial fans - Performance testing using standardized airways (GB/T
1236-2000, idt ISO 5801.1997)
GB/T 1804-2000 General tolerances - Tolerances for linear and angular
dimensions without individual tolerance indications (eqv ISO 2768-1.1989)
GB/T 2888 Methods of noise measurement for fans blowers compressors and
roots blowers
GB/T 3235 Basic types sizes parameters and characteristics curve of fans
GB/T 8923-1988 Rust grades and preparation grades of steel surfaces before
application of paints and related products (eqv ISO 8501-1.1988)
GB/T 9438 Aluminum alloy castings
GB/T 13306 Plates
GB/T 13384 General specifications for packing of mechanical and electrical
product
GB/T 16301-2008 Measurement and evaluation of vibration severity for marine
engine-room auxiliaries
CB 1146.1-1996 Environmental test and engineering guide of ship equipment -
General principles
CB 1146.6-1996 Environmental test and engineering guide of ship equipment -
Impact
CB 1146.8-1996 Environmental test and engineering guide of ship equipment - Tilt
and swing
CB 1146.9-1996 Environmental test and engineering guide of ship equipment -
Vibration
JB/T 6445 Overspeed test for industrial fan impeller
JB/T 6886 Technical specification for draught fan application
JB/T 9101 Fan rotor balance
JB/T 10214 Specification of riveting and welding part for fans
3 Terms and definitions
3.1
rated condition
The highest point of fans’ theoretical design working efficiency is fans’ rated condition.
That is the work point determined by the pressure and flow at the rated point.
3.2
standard condition of inspiration
The condition in which the atmospheric pressure is 101 325 Pa; the temperature is
20 °C; the relative humidity is 50%; and the air density is 1.2 kg/m3.
3.3
standard condition of flux
The air volume converted from fans’ actual flow, under the standard condition of
inspiration.
coated, but the exposed surfaces shall get treatment such as polishing and
passivation.
5.3.1.3 The steel-parts of fans shall get galvanization treatment. And the galvanization
thickness shall not be less than 0.045mm. Rust grades of steel materials be used
shall not be less than Grade B specified in GB 8923-1988. Spray rust-removal or
projectile rust-removal shall reach Grade Sa3 specified in GB 8923-1988. Manual and
power-tool rust-removal shall reach Grade St3 specified in GB 8923-1988.
5.3.1.4 Fans’ chassis bottom (the lowest point) shall have a drain plug.
5.3.1.5 Fans’ riveting parts and welding parts shall comply with the specifications of
JB/T 10214.
5.3.1.6 Fans can be made into clockwise rotation (right-handed rotation) or
counterclockwise rotation (left-handed rotation).
Counterclockwise (left-handed rotation) - PLACE the electric-motor flatly. VIEW
from the electric-motor. The impeller rotates counterclockwise when running. It is
represented by "L".
Clockwise (right-handed rotation) - PLACE the electric-motor flatly. VIEW from the
electric-motor. The impeller rotates clockwise when running. It is represented by
"R".
5.3.1.7 Fans’ outlet position can be made into the following basic forms (see Figure 2)
according to impeller’s rotating direction. As needed, the outlet is allowed to adopt the
30° variation forms.
Figure 2 Front-view from the electric-motor
5.3.2 Impeller
5.3.2.1 Impeller surface’s shape and position tolerances shall not exceed the
requirements in Table 3.
Right 180°
Right 135°
Right 225°
Right 270°
Right 315°
Right 45°
Right 90°
Right 0°
Left 90°
Left 0°
Left 45°
Left 315°
Left 270°
Left 225°
Left 180°
Left 135°
fog, and oil mist;
b) Temperature of -25°C~ + 50°C;
c) Relative humidity is less than 95%;
d) Impact;
e) Tilt and swing;
f) Vibration.
6 Test methods
6.1 Appearance
OBSERVE the internal and external surfaces of fans, the surface quality of welding
parts, and riveting parts visually. The test results shall meet the requirements of 5.1.
6.2 Dimension and weight
MEASURE the main dimensions and weight of fans. The results shall meet the
requirements of 5.2.
6.3 Impeller static and dynamic balance
PERFORM the static and dynamic balancing calibration of the impellers according to
the test requirements specified in JB/T 9101. The test results shall meet the
requirements of 5.4.1.
6.4 Impeller overspeed
Impellers shall run for at least 10 min at a speed that exceeds 20% of rated rotate
speed. The evaluation of the preparation before test AND the test results after running
shall be conducted according to the specifications of JB/T 6445. The test results shall
meet the...