GB/T 42627-2023: Safety of machinery -- Perimeter fence guarding system -- Safety requirements
GB/T 42627-2023
GB
NATIONAL STANDARD OF THE
PEOPLE'S REPUBLIC OF CHINA
ICS 13.110
CCS J 09
Safety of machinery - Perimeter fence guarding system -
Safety requirements
ISSUED ON: MAY 23, 2023
IMPLEMENTED ON: DECEMBER 1, 2023
Issued by: State Administration for Market Regulation;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3
Introduction ... 5
1 Scope ... 7
2 Normative references ... 7
3 Terms and definitions ... 7
4 Conditions of use ... 10
5 Safety requirements ... 10
5.1 Dimensions ... 10
5.2 Strength ... 11
5.3 Perimeter fence ... 12
5.4 Safety door ... 12
5.5 Interlocking devices ... 13
6 Instructions for use ... 13
6.1 General requirements ... 13
6.2 Residual risk ... 13
6.3 Installation instructions ... 13
6.4 Operating instructions ... 14
6.5 Inspection and maintenance ... 14
6.6 Disassembly of perimeter fence guarding system ... 15
Appendix A (Informative) Pendulum impact test method for testing the impact
resistance of perimeter fences ... 16
References ... 21
Safety of machinery - Perimeter fence guarding system -
Safety requirements
1 Scope
This document specifies the conditions of use, safety requirements, and instructions for
use of perimeter fence guarding systems.
This document applies to perimeter fence guarding systems used in industrial areas.
2 Normative references
The following documents contain the provisions which, through normative reference in
this document, constitute the essential provisions of this document. For the dated
referenced documents, only the versions with the indicated dates are applicable to this
document; for the undated referenced documents, only the latest version (including all
the amendments) is applicable to this document.
GB/T 15706-2012 Safety of machinery - General principles for design - Risk
assessment and risk reduction
GB/T 18831-2017 Safety of machinery - Interlocking devices associated with
guards - Principles for design and selection
GB/T 23821-2022 Safety of machinery - Safety distances to prevent hazard zones
being reached by upper and lower limbs
GB/T 42598 Safety of machinery - Instruction handbook - General drafting
principles
3 Terms and definitions
The terms and definitions defined in GB/T 15706-2012 and the following apply to this
document.
3.1 perimeter fence guarding system
Integration of perimeter fences, security doors, and interlocking devices.
NOTE: The perimeter fence guarding system is used to physically isolate a certain area or restrict people
from entering the danger zone. The schematic diagram is shown in Figure 1.
3.4 interlocking device
interlock
Mechanical, electrical, or other types of devices used to prevent hazardous machine
functions from operating under specified conditions (usually as long as the guarding
device is not closed).
[Source: GB/T 15706-2012, 3.28.1]
3.5 safety distance
safe separation distance
Sr
The minimum distance between the protective structure and the danger zone.
[Source: GB/T 23821-2022, 3.2]
3.6 tool
Implements designed for tightening operations.
NOTE: Temporary implements such as special keys or wrenches, coins, or nail files cannot be considered
tools.
[Source: GB/T 8196-2018, 3.7, with modification]
4 Conditions of use
The working environment of the perimeter fence guarding system shall not exceed the
corrosive working environment requirements specified in the product manual.
The ground on which the perimeter fence guarding system is fixed shall be smooth and
hardened.
5 Safety requirements
5.1 Dimensions
5.1.1 Before the height of the perimeter fence is determined, the severity and probability
of occurrence of the injury shall be determined in accordance with 5.5 of GB/T 15706-
2012, and the height of the danger zone (hh) shall be measured. If the danger protected
by the perimeter fence will only cause minor injuries and the probability of occurrence
is low, the height of the perimeter fence (that is, the height of the protective structure
hps) shall be selected in accordance with Table 1 of GB/T 23821-2022, otherwise the
height of the perimeter fence shall be selected in accordance with Table 2 of GB/T
23821-2022.
Without additional protection measures, the lower the height of the perimeter fence, the
greater the distance between the perimeter fence and the danger zone. Generally, the
height of the perimeter fence shall be 1600 mm, 1800 mm, 2000 mm, or 2200 mm.
NOTE: GB/T 16856-2015 5.4 provides guidelines for estimating the severity and probability of injury.
When the height of the perimeter fence is less than 1400 mm, additional protective
measures shall be taken.
5.1.2 Unless the risk assessment results show that it is feasible, the height of the lower
edge of the perimeter fence from the ground shall not exceed 180 mm to prevent people
from entering the danger zone through the lower edge opening.
5.1.3 The grid size of the wire mesh panel of the perimeter fence and the openings of
other panels shall comply with the provisions of 4.2.4 in GB/T 23821-2022.
5.2 Strength
5.2.1 The perimeter fence guarding system shall have sufficient overall structural
strength and maintain impact resistance during the foreseeable life cycle. The pendulum
test method described in Appendix A can be used for testing.
5.2.2 The perimeter fence shall have enough impact resistance to withstand foreseeable
impacts from outside the danger zone, and shall at least meet the function of preventing
people from entering the danger zone. Its basic value shall not be less than 115 J.
NOTE: 115 J is the simulation of the energy before a human body with a total mass of 90 kg hitting the
perimeter fence at a speed of 1.6 m/s from outside the protective zone.
5.2.3 The perimeter fence shall have enough impact resistance to withstand foreseeable
impacts from the danger zone. The impact risk and impact energy of the machine
components or workpieces in the protective zone shall be assessed, and the perimeter
fence with an impact resistance of not less than the foreseeable impact energy shall be
selected. If the impact energy of mechanical moving parts is difficult to evaluate, a
perimeter fence with an impact resistance of not less than 1600 J shall be selected.
NOTE: 1600 J is the simulation of the energy before a mechanical moving part with a total mass of 200
kg hitting the perimeter fence at a running speed of 4 m/s from the protective zone.
of dangerous machine functions, the system shall send out an audible and visual
warning signal.
NOTE: This audible and visual warning is different from the warning when the machine is restarted.
5.5 Interlocking devices
5.5.1 Appropriate interlocking devices shall be selected according to the provisions of
GB/T 18831-2017.
5.5.2 The interlocking device shall be installed securely and meet the requirements of
the instruction manual provided by the interlocking device manufacturer.
6 Instructions for use
6.1 General requirements
6.1.1 The preparation of instructions for use shall comply with the provisions of GB/T
42598.
6.1.2 The instructions for use shall contain the required information about the perimeter
fence guarding system and its safety parameters and functions (such as vertical or
horizontal positioning), including information on installation and maintenance, and
corrosive working environment requirements (if any).
6.2 Residual risk...