GB/T 40821-2021: Test specification for heat exchange system of solar thermal power plant
GB/T 40821-2021
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 27.160
CCS F 12
Test specification for heat exchange system of solar thermal
power plant
ISSUED ON: OCTOBER 11, 2021
IMPLEMENTED ON: MAY 01, 2022
Issued by: State Administration for Market Regulation;
Standardization Administration of the People's Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions... 4
4 Test items and requirements ... 5
5 Measurement content and instrument ... 8
6 Measurement methods ... 9
7 System performance test ... 11
8 Test report ... 16
Annex A (informative) Schematic diagram of heat exchange system flow and main
measuring point layout ... 18
Test specification for heat exchange system of solar thermal
power plant
1 Scope
This document specifies the general method for performance test of heat exchange
system of solar thermal power plant.
This document is applicable to the steam generation system with heat transfer oil or
molten salt as the heat transfer medium, and the oil-salt heat exchange system with
molten salt as the heat storage medium.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB/T 2624 (all parts), Full differential pressure device installed in a pipe of circular
cross-section measuring fluid flow
GB/T 12145, Quality criterion of water and steam for power plant and steam-
generating equipment
GB/T 14416, Methods for sampling boiler steam
DL/T 5182, Code for design of local equipment installation, piping, cables of I and C
of fossil fuel power plant
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 thermal power input
The sum of all heat input to the boundary of the heat exchange system per unit time.
3.2 thermal power output
The sum of the heat output from the boundary of the heat exchange system per unit
time.
3.3 rated evaporation
The amount of evaporation produced by the steam generation system under the design
parameters of the steam turbine rated operating conditions.
3.4 maximum continuous evaporation
The maximum evaporation produced by the steam generation system under the
parameters of the fully open steam turbine valve.
3.5 thermal efficiency
The ratio of output thermal power to input thermal power.
4 Test items and requirements
4.1 Test items
Test items of heat exchange system:
a) Evaporation;
b) Thermal efficiency;
c) Steam water system mass flow, inlet and outlet temperature, pressure drop;
d) Mass flow, inlet and outlet temperature, pressure drop of thermal oil and molten
salt system;
e) Steam quality.
4.2 Heat exchange system flow and main measuring point layout
The flow chart of the heat exchange system of the solar thermal power station and the
layout of the main measuring points are shown in Figure A.1 to Figure A.5 in Annex A
for details.
4.3 Test program
The test program shall at least include the following:
a) Test purpose;
b) Basic situation of the test system;
c) Test conditions and requirements;
d) Test content;
flow or immediately downstream of the junction. It shall be installed in a position where
the temperature of the inlet and outlet of the test can be accurately measured.
6.2.3 The temperature measuring point shall be close to the corresponding pressure
measuring point.
6.2.4 For temperature measurement, a pipe section with uniform velocity and
temperature distribution shall be selected.
6.2.5 Necessary measures shall be taken to prevent the temperature measuring
instrument from distorting the measured data due to conduction, convection and
radiation.
6.2.6 When measuring the temperature of steam and feed water in the pipeline, a plug-
in sleeve shall be used. The insertion depth of the sleeve shall reach 1/3 of the inner
diameter of the pipe. Stay away from the beam flow area.
6.2.7 The temperature data shall comply with the project contract, technical agreement
and other documents. The allowable error shall comply with the provisions in Table 4.
6.2.8 On-site equipment installation and piping design shall comply with the provisions
of DL/T 5182.
6.3 Pressure and differential pressure measurement
6.3.1 Pressure and differential pressure measurement can use single-coil spring tube
pressure gauges, U-tube pressure gauges, electronic micro pressure gauges, membrane
pressure gauges, and pressure and differential pressure transmitters.
6.3.2 The minimum division of the pressure gauge shall meet the requirements of test
accuracy and observation of pressure fluctuations.
6.3.3 When selecting a pressure meter, the measured pressure value shall be within the
range of 1/2 to 3/4 of its full-scale range.
6.3.4 Correction shall be made for the height difference between the pressure point and
the measuring instrument.
6.3.5 The pressure measuring point shall be as close as possible to the inlet and outlet
of the corresponding equipment. The pressure gauge shall be installed in a part that is
not disturbed by high temperature, freezing and vibration.
6.3.6 Pressure data shall comply with the project contract, technical agreement and
other documents. The allowable error shall comply with the provisions in Table 4.
6.3.7 The on-site equipment installation and pipeline design of measuring instruments
shall comply with the provisions of DL/T 5182.
7 System performance test
7.1 Rated evaporation
7.1.1 Test record and measurement content (applicable to heat transfer oil as heat
transfer fluid):
a) Steam pressure and temperature;
b) Feed water flow, pressure and temperature;
c) Steam quality;
d) Temperature reduction water flow;
e) Heat transfer oil flow, pressure and temperature;
f) Molten salt flow, pressure and temperature.
NOTE: From the beginning to the end of the test, the parameters shall be consistent and stable.
7.1.2 Test record and measurement content (applicable to molten salt as heat transfer
fluid):
a) Steam pressure and temperature;
b) Feed water flow, pressure and temperature;
c) Steam quality;
d) Temperature reduction water flow;
e) Molten salt flow, pressure and temperature.
NOTE: From the beginning to the end of the test, the parameters shall be consistent and stable.
7.2 Maximum continuous evaporation
When necessary, measure the maximum continuous evaporation of the steam
generating system, so as to measure the maximum continuous output capacity of the
system.
7.3 Pressure drop of steam water system
The pressure drop of the steam water system is the static pressure difference between
the inlet and outlet, which can be directly measured by a differential pressure gauge.
The inlet and outlet static pressure can also be measured at the same time, and calculated
according to formula (1):
phin - The static pressure at the inlet of the heat transfer oil, in megapascals (MPa);
phout - The static pressure at the outlet of the heat transfer oil, in megapascals (MPa).
NOTE: The correction of the system liquid column weight differential pressure shall be considered
by the testing agency itself.
7.6 Steam quality
7.6.1 Test requirements
7.6.1.1 The steam quality test shall...
Get QUOTATION in 1-minute: Click GB/T 40821-2021
Historical versions: GB/T 40821-2021
Preview True-PDF (Reload/Scroll if blank)
GB/T 40821-2021: Test specification for heat exchange system of solar thermal power plant
GB/T 40821-2021
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 27.160
CCS F 12
Test specification for heat exchange system of solar thermal
power plant
ISSUED ON: OCTOBER 11, 2021
IMPLEMENTED ON: MAY 01, 2022
Issued by: State Administration for Market Regulation;
Standardization Administration of the People's Republic of China.
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Terms and definitions... 4
4 Test items and requirements ... 5
5 Measurement content and instrument ... 8
6 Measurement methods ... 9
7 System performance test ... 11
8 Test report ... 16
Annex A (informative) Schematic diagram of heat exchange system flow and main
measuring point layout ... 18
Test specification for heat exchange system of solar thermal
power plant
1 Scope
This document specifies the general method for performance test of heat exchange
system of solar thermal power plant.
This document is applicable to the steam generation system with heat transfer oil or
molten salt as the heat transfer medium, and the oil-salt heat exchange system with
molten salt as the heat storage medium.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB/T 2624 (all parts), Full differential pressure device installed in a pipe of circular
cross-section measuring fluid flow
GB/T 12145, Quality criterion of water and steam for power plant and steam-
generating equipment
GB/T 14416, Methods for sampling boiler steam
DL/T 5182, Code for design of local equipment installation, piping, cables of I and C
of fossil fuel power plant
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 thermal power input
The sum of all heat input to the boundary of the heat exchange system per unit time.
3.2 thermal power output
The sum of the heat output from the boundary of the heat exchange system per unit
time.
3.3 rated evaporation
The amount of evaporation produced by the steam generation system under the design
parameters of the steam turbine rated operating conditions.
3.4 maximum continuous evaporation
The maximum evaporation produced by the steam generation system under the
parameters of the fully open steam turbine valve.
3.5 thermal efficiency
The ratio of output thermal power to input thermal power.
4 Test items and requirements
4.1 Test items
Test items of heat exchange system:
a) Evaporation;
b) Thermal efficiency;
c) Steam water system mass flow, inlet and outlet temperature, pressure drop;
d) Mass flow, inlet and outlet temperature, pressure drop of thermal oil and molten
salt system;
e) Steam quality.
4.2 Heat exchange system flow and main measuring point layout
The flow chart of the heat exchange system of the solar thermal power station and the
layout of the main measuring points are shown in Figure A.1 to Figure A.5 in Annex A
for details.
4.3 Test program
The test program shall at least include the following:
a) Test purpose;
b) Basic situation of the test system;
c) Test conditions and requirements;
d) Test content;
flow or immediately downstream of the junction. It shall be installed in a position where
the temperature of the inlet and outlet of the test can be accurately measured.
6.2.3 The temperature measuring point shall be close to the corresponding pressure
measuring point.
6.2.4 For temperature measurement, a pipe section with uniform velocity and
temperature distribution shall be selected.
6.2.5 Necessary measures shall be taken to prevent the temperature measuring
instrument from distorting the measured data due to conduction, convection and
radiation.
6.2.6 When measuring the temperature of steam and feed water in the pipeline, a plug-
in sleeve shall be used. The insertion depth of the sleeve shall reach 1/3 of the inner
diameter of the pipe. Stay away from the beam flow area.
6.2.7 The temperature data shall comply with the project contract, technical agreement
and other documents. The allowable error shall comply with the provisions in Table 4.
6.2.8 On-site equipment installation and piping design shall comply with the provisions
of DL/T 5182.
6.3 Pressure and differential pressure measurement
6.3.1 Pressure and differential pressure measurement can use single-coil spring tube
pressure gauges, U-tube pressure gauges, electronic micro pressure gauges, membrane
pressure gauges, and pressure and differential pressure transmitters.
6.3.2 The minimum division of the pressure gauge shall meet the requirements of test
accuracy and observation of pressure fluctuations.
6.3.3 When selecting a pressure meter, the measured pressure value shall be within the
range of 1/2 to 3/4 of its full-scale range.
6.3.4 Correction shall be made for the height difference between the pressure point and
the measuring instrument.
6.3.5 The pressure measuring point shall be as close as possible to the inlet and outlet
of the corresponding equipment. The pressure gauge shall be installed in a part that is
not disturbed by high temperature, freezing and vibration.
6.3.6 Pressure data shall comply with the project contract, technical agreement and
other documents. The allowable error shall comply with the provisions in Table 4.
6.3.7 The on-site equipment installation and pipeline design of measuring instruments
shall comply with the provisions of DL/T 5182.
7 System performance test
7.1 Rated evaporation
7.1.1 Test record and measurement content (applicable to heat transfer oil as heat
transfer fluid):
a) Steam pressure and temperature;
b) Feed water flow, pressure and temperature;
c) Steam quality;
d) Temperature reduction water flow;
e) Heat transfer oil flow, pressure and temperature;
f) Molten salt flow, pressure and temperature.
NOTE: From the beginning to the end of the test, the parameters shall be consistent and stable.
7.1.2 Test record and measurement content (applicable to molten salt as heat transfer
fluid):
a) Steam pressure and temperature;
b) Feed water flow, pressure and temperature;
c) Steam quality;
d) Temperature reduction water flow;
e) Molten salt flow, pressure and temperature.
NOTE: From the beginning to the end of the test, the parameters shall be consistent and stable.
7.2 Maximum continuous evaporation
When necessary, measure the maximum continuous evaporation of the steam
generating system, so as to measure the maximum continuous output capacity of the
system.
7.3 Pressure drop of steam water system
The pressure drop of the steam water system is the static pressure difference between
the inlet and outlet, which can be directly measured by a differential pressure gauge.
The inlet and outlet static pressure can also be measured at the same time, and calculated
according to formula (1):
phin - The static pressure at the inlet of the heat transfer oil, in megapascals (MPa);
phout - The static pressure at the outlet of the heat transfer oil, in megapascals (MPa).
NOTE: The correction of the system liquid column weight differential pressure shall be considered
by the testing agency itself.
7.6 Steam quality
7.6.1 Test requirements
7.6.1.1 The steam quality test shall...