GB/T 1216-2018: External micrometer
GB/T 1216-2018
External micrometer
ICS 17.040.30
J42
National Standards of People's Republic of China
Replace GB/T 1216-2004
Outside diameter micrometer
Published on.2018-05-14
2018-12-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 1216-2004 "outer diameter micrometer". This standard is compared with GB/T 1216-2004, except for editorial modifications.
In addition, the main technical changes are as follows.
--- Scope of application removed the outer diameter micrometer with a graduation value of 0.005mm (see Chapter 1, Chapter 1 of the.2004 edition);
--- Modified the definition of the outer diameter micrometer (see 3.1, 3.1 of the.2004 edition);
--- Increased the type of outer diameter micrometer (see 4.1.1);
--- Increased the type and description of the outer diameter micrometer reading device (see 4.1.2);
--- Modified the basic parameters of the outer diameter micrometer (see 4.2,.2004 version 4.2);
--- Modified the deformation requirements of the ruler (see 5.3.1, 5.3.1 of the.2004 edition);
---Modified the technical requirements for micrometer screw and anvil (see 5.4,.2004 edition 5.4);
--- Revised the technical requirements for interaction (see 5.5, 5.5 and Appendix A of the.2004 edition);
---Modify the "force measuring device" as "locking device" (see 5.6, 5.6 of the.2004 edition);
---Modify "ratchet" as "force measuring device" (see 5.7, 5.7 of.2004 edition);
---Modified the technical requirements of the measuring surface, deleted the appendix "measuring surface deviation value", the corresponding content is placed in the text (see 5.8,.2004 edition)
5.8 and Appendix B);
---Modified the ruler spacing technical requirements (see 5.9.1,.2004 version 5.9.1);
--- Increased the outer diameter micrometer score line coincidence requirement of the graduation value of 0.001mm (see 5.9.5);
---Modified "digital display device" as "counter digital reading device" and modified the corresponding requirements (see 5.10,.2004 edition)
5.10);
--- Revised the technical requirements for the maximum allowable error (see 5.11, 5.11 of the.2004 edition);
--- Revised the technical requirements for proofreading gauges (see 5.12, 5.12 of the.2004 edition);
--- Modified the inspection requirements of the interaction, deleted the appendix "axial yaw and radial oscillating", the corresponding content is placed in the text (see 6.4,
Version 6.4 and Appendix A of the.2004 edition;
---Modified the measurement error of the measurement surface error (see 6.6, 6.6 of.2004 edition);
--- Revised the inspection requirements for the indication error of the outer diameter micrometer (see 6.7, 6.7 of the.2004 edition).
This standard was proposed by the China Machinery Industry Federation.
This standard is under the jurisdiction of the National Standardization Technical Committee for Measuring Instruments (SAC/TC132).
This standard is drafted by. Chengdu Tool Research Institute Co., Ltd.
Participated in the drafting of this standard. Suzhou McLong Measuring Technology Co., Ltd., Guilin Measuring Tool Limited Liability Company, Chengdu Massing Tool
Group Co., Ltd., Harbin Measuring and Cutting Tool Group Co., Ltd., Guilin Guanglu Digital Measurement and Control Co., Ltd., Guangxi Zhuang Autonomous Region
Testing Institute, Liaoning Institute of Metrology.
The main drafters of this standard. Xu Gang, Jiang Zhigang, Huang Xiaobin, Wei Gaihong, Luo Weibing, Zhang Wei, Dong Zhongxin, Chen Ping, Ding Wen.
The previous versions of the standards replaced by this standard are.
---GB/T 1216-1975, GB/T 1216-1985, GB/T 1216-2004.
Outside diameter micrometer
1 Scope
This standard specifies the terms and definitions, types and basic parameters, requirements, and external diameter micrometers (excluding electronic digital display outer diameter micrometers).
Inspection methods and signs and packaging.
This standard applies to outer diameter micrometers with graduation values of 0.01mm, 0.001mm, 0.002mm and upper limit of measurement range up to 1000mm.
(Does not include electronic digital display outer diameter micrometer).
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1800.2-2009 Geometrical Product Specifications (GPS) Limits and fits. Part 2. Standard tolerance classes and
Limit deviation table
GB/T 17163-2008 Geometric quantity measuring instrument terminology basic terminology
GB/T 17164-2008 Geometric quantity measuring instrument terminology product terminology
3 Terms and definitions
The following terms and definitions as defined in GB/T 17163-2008 and GB/T 17164-2008 apply to this document.
3.1
Using the screw pair to convert the rotation angle of the micrometer screw into the axial displacement of the micrometer screw, and the distance between the two measuring surfaces on the scale frame
An external measuring device that performs readings.
Note. Rewrite GB/T 17164-2008, definition 2.3.2.
3.2
Micrometer maximum allowable error maximumpermissibleerrorofmeasuringhead
The influence of the anvil and the ruler is neglected, and only the maximum allowable error of the indication of the micrometer is specified.
4 type and basic parameters
4.1 type
4.1.1 Outer diameter micrometer main type
The type of the outer diameter micrometer is shown in Figure 1, and the illustration is for illustration purposes only.
The anvil of the outer diameter micrometer can be made fixed, replaceable or adjustable (or movable).
The outer diameter micrometer readings have analog scale readings and counter digital readings.
The outer diameter micrometer should be equipped with a zero adjustment tool. The outer diameter micrometer of the lower limit of the measurement range greater than or equal to 25mm should be accompanied by proofreading.
Measuring rod.
a) Fixed anvil fixed micrometer
b) Anvil can be replaced with an outer diameter micrometer
Figure 1 Schematic diagram of the outer diameter micrometer
c) Anvil can adjust the position (or movable) outer diameter micrometer
Description.
1---measurement surface;
2---anvil;
3---micrometer screw;
4---foot frame;
5---insulation device;
6---locking device;
7---fixed casing;
8 --- baseline;
9 --- ruler analog reading device;
10---microtube;
11---force measuring device;
12---counter digital reading device;
13---replaceable anvil;
14---Adjustable position (or movable) anvil.
Figure 1 (continued)
4.1.2 Outside diameter micrometer reading device
4.1.2.1 Analog scale reading device
The analog scale reading device is shown in Figures 2 and 3.
Description.
1---main ruler;
2---sub-scale.
Note. The reading in the figure is 35.04mm.
Figure 2 Analog scale reading device (the pitch of the micro screw is 0.5mm, the graduation value is 0.01mm)
Description.
1---main ruler;
2---sub-scale;
3--- vernier ruler.
Note. The reading in the figure is 5.005mm.
Figure 3 Analog scale reading device (the pitch of the micro screw is 0.5mm, the graduation value is 0.001mm)
4.1.2.2 Counter digital reading device
The counter digital reading device is shown in Figure 4.
Description.
1---Counter digital reading device.
Figure 4 counter digita...
Get QUOTATION in 1-minute: Click GB/T 1216-2018
Historical versions: GB/T 1216-2018
Preview True-PDF (Reload/Scroll if blank)
GB/T 1216-2018: External micrometer
GB/T 1216-2018
External micrometer
ICS 17.040.30
J42
National Standards of People's Republic of China
Replace GB/T 1216-2004
Outside diameter micrometer
Published on.2018-05-14
2018-12-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 1216-2004 "outer diameter micrometer". This standard is compared with GB/T 1216-2004, except for editorial modifications.
In addition, the main technical changes are as follows.
--- Scope of application removed the outer diameter micrometer with a graduation value of 0.005mm (see Chapter 1, Chapter 1 of the.2004 edition);
--- Modified the definition of the outer diameter micrometer (see 3.1, 3.1 of the.2004 edition);
--- Increased the type of outer diameter micrometer (see 4.1.1);
--- Increased the type and description of the outer diameter micrometer reading device (see 4.1.2);
--- Modified the basic parameters of the outer diameter micrometer (see 4.2,.2004 version 4.2);
--- Modified the deformation requirements of the ruler (see 5.3.1, 5.3.1 of the.2004 edition);
---Modified the technical requirements for micrometer screw and anvil (see 5.4,.2004 edition 5.4);
--- Revised the technical requirements for interaction (see 5.5, 5.5 and Appendix A of the.2004 edition);
---Modify the "force measuring device" as "locking device" (see 5.6, 5.6 of the.2004 edition);
---Modify "ratchet" as "force measuring device" (see 5.7, 5.7 of.2004 edition);
---Modified the technical requirements of the measuring surface, deleted the appendix "measuring surface deviation value", the corresponding content is placed in the text (see 5.8,.2004 edition)
5.8 and Appendix B);
---Modified the ruler spacing technical requirements (see 5.9.1,.2004 version 5.9.1);
--- Increased the outer diameter micrometer score line coincidence requirement of the graduation value of 0.001mm (see 5.9.5);
---Modified "digital display device" as "counter digital reading device" and modified the corresponding requirements (see 5.10,.2004 edition)
5.10);
--- Revised the technical requirements for the maximum allowable error (see 5.11, 5.11 of the.2004 edition);
--- Revised the technical requirements for proofreading gauges (see 5.12, 5.12 of the.2004 edition);
--- Modified the inspection requirements of the interaction, deleted the appendix "axial yaw and radial oscillating", the corresponding content is placed in the text (see 6.4,
Version 6.4 and Appendix A of the.2004 edition;
---Modified the measurement error of the measurement surface error (see 6.6, 6.6 of.2004 edition);
--- Revised the inspection requirements for the indication error of the outer diameter micrometer (see 6.7, 6.7 of the.2004 edition).
This standard was proposed by the China Machinery Industry Federation.
This standard is under the jurisdiction of the National Standardization Technical Committee for Measuring Instruments (SAC/TC132).
This standard is drafted by. Chengdu Tool Research Institute Co., Ltd.
Participated in the drafting of this standard. Suzhou McLong Measuring Technology Co., Ltd., Guilin Measuring Tool Limited Liability Company, Chengdu Massing Tool
Group Co., Ltd., Harbin Measuring and Cutting Tool Group Co., Ltd., Guilin Guanglu Digital Measurement and Control Co., Ltd., Guangxi Zhuang Autonomous Region
Testing Institute, Liaoning Institute of Metrology.
The main drafters of this standard. Xu Gang, Jiang Zhigang, Huang Xiaobin, Wei Gaihong, Luo Weibing, Zhang Wei, Dong Zhongxin, Chen Ping, Ding Wen.
The previous versions of the standards replaced by this standard are.
---GB/T 1216-1975, GB/T 1216-1985, GB/T 1216-2004.
Outside diameter micrometer
1 Scope
This standard specifies the terms and definitions, types and basic parameters, requirements, and external diameter micrometers (excluding electronic digital display outer diameter micrometers).
Inspection methods and signs and packaging.
This standard applies to outer diameter micrometers with graduation values of 0.01mm, 0.001mm, 0.002mm and upper limit of measurement range up to 1000mm.
(Does not include electronic digital display outer diameter micrometer).
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1800.2-2009 Geometrical Product Specifications (GPS) Limits and fits. Part 2. Standard tolerance classes and
Limit deviation table
GB/T 17163-2008 Geometric quantity measuring instrument terminology basic terminology
GB/T 17164-2008 Geometric quantity measuring instrument terminology product terminology
3 Terms and definitions
The following terms and definitions as defined in GB/T 17163-2008 and GB/T 17164-2008 apply to this document.
3.1
Using the screw pair to convert the rotation angle of the micrometer screw into the axial displacement of the micrometer screw, and the distance between the two measuring surfaces on the scale frame
An external measuring device that performs readings.
Note. Rewrite GB/T 17164-2008, definition 2.3.2.
3.2
Micrometer maximum allowable error maximumpermissibleerrorofmeasuringhead
The influence of the anvil and the ruler is neglected, and only the maximum allowable error of the indication of the micrometer is specified.
4 type and basic parameters
4.1 type
4.1.1 Outer diameter micrometer main type
The type of the outer diameter micrometer is shown in Figure 1, and the illustration is for illustration purposes only.
The anvil of the outer diameter micrometer can be made fixed, replaceable or adjustable (or movable).
The outer diameter micrometer readings have analog scale readings and counter digital readings.
The outer diameter micrometer should be equipped with a zero adjustment tool. The outer diameter micrometer of the lower limit of the measurement range greater than or equal to 25mm should be accompanied by proofreading.
Measuring rod.
a) Fixed anvil fixed micrometer
b) Anvil can be replaced with an outer diameter micrometer
Figure 1 Schematic diagram of the outer diameter micrometer
c) Anvil can adjust the position (or movable) outer diameter micrometer
Description.
1---measurement surface;
2---anvil;
3---micrometer screw;
4---foot frame;
5---insulation device;
6---locking device;
7---fixed casing;
8 --- baseline;
9 --- ruler analog reading device;
10---microtube;
11---force measuring device;
12---counter digital reading device;
13---replaceable anvil;
14---Adjustable position (or movable) anvil.
Figure 1 (continued)
4.1.2 Outside diameter micrometer reading device
4.1.2.1 Analog scale reading device
The analog scale reading device is shown in Figures 2 and 3.
Description.
1---main ruler;
2---sub-scale.
Note. The reading in the figure is 35.04mm.
Figure 2 Analog scale reading device (the pitch of the micro screw is 0.5mm, the graduation value is 0.01mm)
Description.
1---main ruler;
2---sub-scale;
3--- vernier ruler.
Note. The reading in the figure is 5.005mm.
Figure 3 Analog scale reading device (the pitch of the micro screw is 0.5mm, the graduation value is 0.001mm)
4.1.2.2 Counter digital reading device
The counter digital reading device is shown in Figure 4.
Description.
1---Counter digital reading device.
Figure 4 counter digita...