Ir directamente a la información del producto
1 de 5

PayPal, credit cards. Download editable-PDF & invoice in 1 second!

GB 5009.243-2016 English PDF (GB5009.243-2016)

GB 5009.243-2016 English PDF (GB5009.243-2016)

Precio habitual $90.00 USD
Precio habitual Precio de oferta $90.00 USD
Oferta Agotado
Los gastos de envío se calculan en la pantalla de pago.
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB 5009.243-2016
Historical versions: GB 5009.243-2016
Preview True-PDF (Reload/Scroll if blank)

GB 5009.243-2016: National food safety standard -- Determination of Heterocyclic Amines in High Temperature Cooked Foods
GB 5009.243-2016
National food safety standard - Determination of Heterocyclic Amines in High Temperature Cooked Foods
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
National Food Safety Standard -
Determination of Heterocyclic Amine
Substances in High-temperature Cooked Foods
Issued on. August 31, 2016 Implemented on. March 01, 2017
Issued by. National Health and Family Planning Commission of the PRC
Table of Contents
1 Scope ...3 
2 Principles ...3 
3 Reagents and materials ...3 
4 Instruments and apparatuses ...5 
5 Analytical procedures ...6 
6 Result calculation ...8 
7 Recovery rate and precision ...8 
8 Other ...8 
Appendix A Gradient elution procedures ...9 
Appendix B Mass spectrometry reference conditions ...10 
Appendix C Standard solution chromatogram ...11 
National Food Safety Standard -
Determination of Heterocyclic Amine
Substances in High-temperature Cooked Foods
1 Scope
This Standard specifies the liquid chromatography-mass spectrometry/mass
spectrometry for the determination of heterocyclic amines in high-temperature
cooked foods such as 2-amino-3,4-dimethylimidazo [4,5-f] quinoline (MeIQ), 2-
amino-3,8-dimethylimidazo [4,5-f] quinoline (MeIQx), 2-amino-3,4,8-
trimethylimidazo [4,5-f] quinoline (4,8-DiMeIQx), 2-amino-3,7,8-
trimethylimidazo [4,5-f] quinoline (7,8-DiMeIQx), 2-amino-1-methyl-6-phenyl-
imidazo [4,5-b] pyridine (PhIP).
This Standard applies to the determination of MeIQ, MeIQx, 4,8-DiMeIQx, 7,8-
DiMeIQx, PhIP in grilled fish, barbecue, and their products.
2 Principles
The sample is extracted using sodium hydroxide/methanol solution, purified by
solid-phase extraction column, detected by liquid chromatography-tandem
mass spectrometry, and quantified by internal standard method.
3 Reagents and materials
Unless otherwise specified, the reagents used are analytically pure; and the
water is Grade 1 water specified in GB/T 6682.
3.1 Reagents
3.1.1 Sodium hydroxide.
3.1.2 Ammonium acetate. Purity≥98%.
3.1.3 Methanol. chromatographically pure.
3.1.4 Ethanol. chromatographically pure.
3.1.5 N-hexane. chromatographically pure.
3.1.6 Dichloromethane. chromatographically pure.
3.1.7 Acetonitrile. chromatographically pure.
3.1.8 Glacial acetic acid. chromatographically pure.
3.2 Reagents preparation
3.2.1 Sodium hydroxide solution (40 g/L). WEIGH 40.0 g of sodium hydroxide;
USE water to dissolve and dilute to 1 L.
3.2.2 Sodium hydroxide solution (4 g/L). MEASURE and TAKE 50 mL of 40 g/L
sodium hydroxide solution (3.2.1); ADD 450 mL of water; MIX well.
3.2.3 40 g/L sodium hydroxide-methanol mixed solution (70+30, volume
fraction). MEASURE and TAKE 70 mL of 40 g/L sodium hydroxide solution
(3.2.1); ADD 30 mL of methanol; MIX well.
3.2.4 4 g/L sodium hydroxide-methanol mixed solution (45+55, volume fraction).
MEASURE and TAKE 45 mL of 4 g/L sodium hydroxide solution (3.2.2); ADD
55 mL of methanol; MIX well.
3.2.5 Ethanol-dichloromethane mixed solution (10+90, volume fraction).
MEASURE and TAKE 10 mL of ethanol; ADD 90 mL of dichloromethane; MIX
well.
3.2.6 Acetonitrile-water solution (5+95, volume fraction). MEASURE and TAKE
5 mL of acetonitrile; ADD 95 mL of water; MIX well.
3.2.7 Acetic acid-ammonium acetate buffer solution. WEIGH 1.155 g of
ammonium acetate; USE 450 mL of water to dissolve; USE acetic acid to adjust
the pH to 5.0±0.5; ADD water to dilute to 500 mL.
3.2.8 Acetic acid buffer solution-acetonitrile mixed solution (50+50, volume
fraction). MEASURE and TAKE 50 mL of acetic acid-ammonium acetate buffer
solution (3.2.7); ADD 50 mL of acetonitrile; MIX well.
3.3 Standards
3.3.1 Heterocyclic amine standard substances. MeIQ (C12H12N4, 77094-11-2),
MeIQx (C11H11N5, 77500-04-0), 4,8-DiMeIQx (C12H13N5, 95896-78-9), 7,8-
DiMeIQx (C12H13N5, 92180-79-5), PhIP (C13H12N4, 105650-23-5).The purity is
greater than 99%.
3.3.2 Internal standard standard substance 4,7,8-TriMeIQx (C13H15N5, 132898-
07-8).The purity is greater than 99%.
5 Analytical procedures
5.1 Sample preparation
The edible portion from grilled fish, barbecue, and their products is taken,
mashed, and mixed; and after being labelled, stored frozen at -18 °C.
5.2 Sample processing
5.2.1 Extraction. WEIGH 2 g (accurate to 0.01 g) of sample into a 50 mL
centrifuge tube; ADD 200 μL of internal standard working solution (3.4.4); and
then ADD 9.8 mL of 40 g/L sodium hydroxide-methanol mixed solution (3.2.3);
homogenize for 1 min.The homogenizer cutter head is washed twice using 5.0
mL of 40 g/L sodium hydroxide-methanol mixed solution (3.2.3).The washing
liquid is combined into a sample extraction centrifuge tube.The sample is
centrifuged at 10000 r/min for 10 min to be purified.
5.2.2 Purification. The solid-phase extraction column (3.5.2) is activated in
advance subsequently using 2 mL of methanol and 3 mL of 4 g/L sodium
hydroxide solution (3.2.2).MEASURE and TAKE 10 mL of extract into the solid-
phase extraction column.After discarding the effluent, subsequently USE 3 mL
of 4 g/L sodium hydroxide-methanol mixed solution (3.2.4) and 2 mL of n-
hexane to rinse.After each rinse, the rinse solution in the column shall be
drained.Finally, USE 1.5 mL of ethanol-dichloromethane solution (3.2.5) to
elute.The elution flow rate shall be less than 1 mL/min.After the eluent is
nitrogen-concentrated in a water bath at 35 °C to near dryness, 1.0 mL of acetic
acid buffer solution-acetonitrile mixed solution (3.2.8) is added; vortex-mixed;
and filtered through the microporous membrane (3.5.1) to the injection vial, for
assay determination on the machine.
5.3 Determination
5.3.1 Liquid chromatographic conditions
5.3.1.1 Chromatographic column. C18 column (2.5 μm, 100 mm×2.1 mm) or
equivalent.
5.3.1.2 Mobile phase. A is acetic acid-ammonium acetate buffer solution (3.2.7).
B is acetonitrile.For the gradient elution procedures, see Appendix A, A.1.
5.3.1.3 Flow rate. 0.3 mL/min.
5.3.1.4 Column temperature. 40 °C.
5.3.1.5 Injection volume. 5 μL.

Ver todos los detalles