Zu Produktinformationen springen
1 von 6

PayPal, credit cards. Download editable-PDF and invoice in 1 second!

GB/T 693-1996 English PDF (GBT693-1996)

GB/T 693-1996 English PDF (GBT693-1996)

Normaler Preis $100.00 USD
Normaler Preis Verkaufspreis $100.00 USD
Sale Ausverkauft
Versand wird beim Checkout berechnet
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB/T 693-1996
Historical versions: GB/T 693-1996
Preview True-PDF (Reload/Scroll if blank)

GB/T 693-1996: Chemical reagent. Sodium acetate trihydrate
GB/T 693-1996
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 71.040.30
G 63
Replacing GB 693-85
Chemical reagent - Sodium acetate trihydrate
ISSUED ON: AUGUST 22, 1996
IMPLEMENTED ON: FEBRUARY 01, 1997
Issued by: State Bureau of Technical Supervision
Table of Contents
Foreword ... 3 
1 Scope ... 5 
2 Normative references ... 5 
3 Characteristics ... 6 
4 Specifications ... 6 
5 Tests... 7 
6 Inspection rules ... 12 
7 Packaging and marks ... 12 
Annex A (Normative) Treatment and regeneration method for strong acid cation
exchange resin ... 13 
Chemical reagent - Sodium acetate trihydrate
Molecular formula: CH3C00Na • 3H2O
Relative molecular mass: 136.08
1 Scope
This Standard specifies technical requirements, test methods, inspection rules,
packaging and marks for chemical reagent - sodium acetate trihydrate.
2 Normative references
The following standards contain provisions which, through reference in this
Standard, constitute provisions of this Standard. At the time of publication, the
editions indicated are valid. All standards are subject to revision. The parties
who are using this Standard shall explore the possibility of using the latest
version of the following standards.
GB/T 601-88, Chemical Reagent - Preparations of Standard Volumetric
Solutions
GB/T 602-88, Chemical reagent - Preparations of standard solutions for
impurity
GB/T 603-88, Chemical reagent - Preparations of reagent solutions for use
in test methods
GB/T 619-88, Chemical reagent - Regulations for sampling and acceptance
GB/T 3914-83, Chemical reagents - The general rules of anodic stripping
voltammetry
GB 6682-92, Water for laboratory use - Specifications (eqv ISO 3696:1987)
GB/T 9723-88, Chemical reagent - General rules for flame atomic absorption
spectrometry
GB/T 9724-88, Chemical reagent - General rule for the determination of pH
(eqv ISO 6353-1:1982)
GB/T 9727-88, Chemical reagent - General method for the determination of
phosphate (eqv ISO 6353-1:1982)
Where,
X - Percentage of mass of sodium acetate trihydrate, %;
V1 - Volume of sodium hydroxide standard titration solution, mL;
V2 - Volume of sodium hydroxide standard titration solution in blank test, mL;
c - Concentration of sodium hydroxide standard titration solution, mol/L;
136.1 - Molar mass of sodium acetate trihydrate [M(CH3COONa• 3H2O)], g/mol;
m - Sample mass, g.
5.2 pH
Measure according to provisions of GB/T 9724.
5.3 Clarity test
Weigh 20g of sample. Dissolve in 100mLof water. Its turbidity must not exceed
following clarity standards specified in HG/T 3-1168-78:
Guaranteed reagent ……………... No.2;
Analytical reagent ………………... No.3;
Chemical pure ……………...……... No.5.
5.4 Water insoluble matter
Weigh 50g of sample. Dissolve in 300mLof boiling water. Cool to room
temperature. Measure according to provision of GB/T 9738.
5.5 Chloride
5.5.1 Preparation of test solution
Weigh 20g of sample. Dissolve in water. Dilute to 50mL.
5.5.2 Determination method
Take 5mLof test solution. Dilute to 10mL. Add 4.5mL of nitric acid solution (25%)
to acidify. Measure according to provisions of GB/T 9729. Solution turbidity
must not exceed standard comparison solution.
Preparation of standard comparison solution is to take chloride standard
solution that contains following quantities:
Guaranteed reagent ……………... 0.006mg Cl;
Guaranteed reagent, Analytical reagent ……………... 0.01mg Al;
Chemical pure …………………………………………... 0.02mg Al.
Dilute to 10mL. Perform same treatment as same volume test solution.
5.9 Potassium
Measure according to provisions of GB/T 9723.
5.9.1 Instrument conditions
Light source: potassium hollow cathode lamp;
Wavelength: 766.5nm;
Flame: Acetylene-air.
5.9.2 Determination method
Weigh 5g of sample. Dissolve in water. Add 5mLof hydrochloric acid solution
(20%). Dilute to 100mL.Take 10mL, four portions in total. Measure according to
provisions of 6.2.2 in GB/T 9723-88.
5.10 Calcium
Measure according to provisions of GB/T 9723-88.
5.10.1 Instrument conditions
Light source: calcium hollow cathode lamp;
Wavelength: 422.7nm;
Flame: Acetylene-air.
5.10.2 Determination method
Weigh 25g of sample. Dissolve in water. Add 20mLof hydrochloric acid solution
(20%). Dilute to 100mL. Take 20mL (take 8mLfor chemical pure), four portions
in total. Measure according to provisions of 6.2.2 in GB/T 9723-88.
5.11 Iron
Take 5mLof test solution (5.5.1). Dilute to 10mL. Use hydrochloric acid solution
(15%) to adjust pH value to 2. Measure according to provisions of GB/T 9739.
Red of solution must not be darker than standard comparison solution.
Preparation of standard comparison solution is to take iron standard solution
that contains following quantities:
Annex A
(Normative)
Treatment and regeneration method for strong acid cation
exchange resin
A.1 Instruments
A.1.1 Exchange column material: glass tube or polyethylene tube.
A.1.2 Exchange column inner diameter: 10mm~20mm.
A.1.3 Resin bed height: about 400mm (recombinant resin volume accounts for
2/3 of exchange column height).
A.1.4 Resin particle size: 0.2mm~0.8mm.
A.2 Treatment method
Take an appropriate amount of strong acid cation exchange resin into a beaker
(for dry resin, use saturated sodium chloride solution to soak first; then gradually
dilute sodium chloride solution in case resin is broken from expanding). Use
water to rinse till it is clear. Add water to soak 12h~24h to make it completely
expanded. After draining water, soak it in 95% ethanol for 24h. Use water to
rinse it till it is alcohol-free. Add hydrochloric acid solution (1+3) to soak 2h~3h.
Use water to rinse it to neutral. Add sodium hydroxide solution (100g/L). Soak
2h~3h. Use water to rinse it to neutral. Then use hydrochloric acid solution (1+3)
to rinse and soak 24h.Stir frequently. Use hydrochloric acid solution (1+3) to
rinse three times.
Load resin that is processed as above into exchange column. Use 400mLof
hydrochloric acid solution (1+3) to rinse resin at a flow of 10mL/min. Then use
water to rinse till washing fluid if neutral. Use water to soak, for use.
A.3 Regeneration method
Move invalid strong acid cation exchange resin into a beaker. Use hydrochloric
acid solution (1+3) to rinse three times. Soak 21h. Stir frequently. Discharge
hydrochloric acid solution. Use hydrochloric acid solution (1+3) to rinse three
times.
Load resin that is processed as above into exchange column. Use 400mLof
hydrochloric acid solution (1+3) to rinse resin at a flow of 10mL/min. Then use
water to rinse till dripping solution is neutral. Use water to soak, for use.
__________ END __________