GB/T 26837-2011: Non-destructive testing instruments -- Stationary type and movable type industrial X-ray radiographic equipment
GB/T 26837-2011
GB
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 19.100
N 78
Non-destructive testing instruments - Stationary type and
movable type industrial X-ray radiographic equipment
ISSUED ON. JULY 29, 2011
IMPLEMENTED ON. DECEMBER 01, 2011
Issued by. General Administration of Quality Supervision Inspection and
Quarantine of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 4
1 Scope ... 5
2 Normative references ... 5
3 Product classification ... 6
3.1 Product model ... 6
3.2 Main technical parameters ... 6
4 Requirements ... 7
4.1 Conditions of use... 7
4.2 Performance ... 7
4.3 Stability ... 9
4.4 Radiation protection and safety ... 10
4.5 Appearance requirements ... 11
5 Test methods ... 11
5.1 Test conditions ... 11
5.2 Main instruments and appliances for testing ... 11
5.3 Penetration determination ... 12
5.4 Determination of relative sensitivity ... 14
5.5 Determination of ray radiation angle and radiation field uniformity ... 15
5.6 Determination of X-ray machine’s timer error ... 17
5.7 Determination of tube-voltage error ... 17
5.8 Determination of X-ray machine’s tube-voltage’s regulated-device ... 19
5.9 Determination of overcurrent protection ... 19
5.10 Determination of overvoltage protection ... 19
5.11 Determination of temperature protection device ... 20
5.12 Determination of tube-current’s under-milliamp protective device ... 20
5.13 Determination of continuous working stability ... 20
5.14 Determination of output voltage of voltage-regulated circuit ... 21
5.15 Determination of leakage ray’s air kerma rate ... 21
5.16 Determination of insulation resistance of high-voltage circuit ... 21
5.17 Determination of grounding resistance of grounding protective device ... 21
5.18 Determination of insulation strength of low-voltage circuits ... 22
5.19 Determination of insulation strength of high-voltage circuits ... 22
5.20 Determination of primary insulation resistance of filament transformer to
ground ... 22
5.21 Determination of secondary insulation strength of controller to ground ... 23
5.22 Cleanliness testing ... 23
5.23 Appearance quality testing ... 23
5.24 Determination of leakage ... 23
5.25 Transport storage environment test ... 23
5.26 Packaging test ... 24
5.27 Normal working test when power supply voltage fluctuats ... 24
6 Inspection rules ... 25
6.1 Exit-factory inspection ... 25
6.2 Type inspection ... 26
7 Marking, packaging, transportation and storage ... 27
7.1 Marking ... 27
7.2 Packaging ... 27
7.3 Transportation and storage ... 28
Appendix A (Normative) Calibration test block for X-ray machine ... 29
Non-destructive testing instruments - Stationary type and
movable type industrial X-ray radiographic equipment
1 Scope
This standard specifies the technical requirements, test methods, inspection
rules, marking, packaging, transportation and storage of stationary type and
movable type industrial X-ray radiographic equipment (hereinafter referred to
as X-ray machines).
This standard applies to stationary type and movable type industrial X-ray
radiographic equipment which has a tube-voltage not exceeding 500 kV.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 9582-2008 Photography - Industrial radiographic films - Determination
of ISO speed ISO average gradient and ISO gradients G2 and G4 when
exposed to X-and Gamma-radiation
GB/T 13384 General specifications for packing of mechanical and electrical
product
GB 18871-2002 Basic standards for protection against ionizing radiation and
for the safety of radiation sources
GB 22448-2008 Protection rules for industrial X-ray radiographic equipment
up to 500 kV
JB/T 6220-2004 The densimeter for radiography
JB/T 7808-2010 Non-destructive testing instruments Main parameter series
for the industrial X-ray equipment
JB/T 9329 Basic environmental conditions and testing methods for
instruments transportation and storage in the transportation
radiation field. The radiation field of the circumferential X-ray machine shall be
uniform, the density difference in the center plane shall be less than 0.4, the
radiation angle error shall be +5°.
4.2.4 The X-ray machine shall be equipped with the exposure cumulative timer,
to record the cumulative exposure time of the X-ray tube.
4.2.5 The X-ray machine shall have a timer that controls the duration of
exposure. The maximum error of the timing shall not be greater than ±2% of the
indicated value of the measured point.
4.2.6 The maximum allowable error of the X-ray machine tube-voltage shall not
exceed ± 5% of the measured value (power frequency, oil-insulated machine).
4.2.7 The X-ray machine shall be provided with a tube-voltage regulated-device,
the starting tube-voltage shall not be greater than 20% of the rated tube-voltage.
4.2.8 The X-ray machine shall be equipped with an overvoltage protection
device. When the tube-voltage exceeds the rated tube-voltage of 5 kV ~ 10 kV,
the high-voltage shall be disconnected.
4.2.9 The X-ray machine shall be provided with a temperature protection device.
When the temperature inside the generator reaches 60 °C ± 5 °C, the high-
voltage shall be disconnected.
4.2.10 The X-ray machine shall be provided with an under-millimeter protection
device. When the tube-current is less than 0.5 mA, the high-voltage shall be
disconnected.
4.2.11 The X-ray machine shall be equipped with an overcurrent protection
device. When the tube-current is greater than the rated tube-current of 1 mA,
the high-voltage shall be disconnected.
4.3 Stability
4.3.1 The X-ray machine shall work continuously for 10 times in accordance
with the specified working procedures. There shall be no abnormal phenomena
during the test, the temporary load rate shall conform to the nominal data. Each
continuous working time shall be no less than 10 minutes.
4.3.2 The X-ray machine shall be equipped with a voltage stabilized-circuit. The
tube-voltage fluctuation shall be within ±2%; the tube-current fluctuation shall
be within ±0.5 mA.
to ground shall be not less than 5 MΩ.
4.4.6 The primary insulation resistance of X-ray machine’s filament transformer
to ground is tested by the 1000 V, 50 Hz AC, there shall be no abnormality after
withstanding voltage for 2 min.
4.4.7 The X-ray machine shall have a grounding protection device; the
grounding resistance shall be less than 0.5 Ω.
4.4.8 The impurities of the X-ray machine’s controller and high-voltage
generator (power frequency, oil-insulated) shall not be more than 100 mg.
4.4.9 The cable connector and plug connection of the X-ray machine are
convenient to disassemble. The number of thread is not less than 3 and has a
protective cover.
4.4.10 The X-ray machine’s generator assembly shall be capable of locking at
any desired location and capable of emitting X-rays in the desired direction. The
generator support shall be able to support the X-ray generator, it has 3 degrees
of freedom, be sensitive and has brakes.
4.4.11 The X-ray machine generator and cooling c...