GB/T 18271.3-2017: Process measurement and control devices -- General methods and procedures for evaluating performance -- Part 3: Tests for the effects of influence quantities
GB/T 18271.3-2017
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 25.040.40
N 10
GB/T 18271.3-2017 / IEC 61298-3:2008
Replacing GB/T 18271.3-2000
Process measurement and control devices - General
methods and procedures for evaluating performance -
Part 3: Tests for the effects of influence quantities
(IEC 61298-3:2008, IDT)
ISSUED ON: JULY 12, 2017
IMPLEMENTED ON: FEBRUARY 01, 2018
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of the PRC;
Standardization Administration of the PRC.
Table of Contents
Foreword ... 4 
1 Scope ... 8 
2 Normative references ... 8 
3 Terms and definitions ... 10 
4 General considerations ... 12 
4.1 Criteria ... 12 
4.2 General procedures ... 12 
4.3 General EMC requirements ... 13 
5 Ambient temperature effects ... 14 
5.1 Criteria ... 14 
5.2 Test procedure ... 14 
6 Ambient relative humidity effects ... 15 
7 Vibration ... 16 
7.1 General considerations ... 16 
7.2 Initial resonance search ... 18 
7.3 Endurance conditioning by sweeping ... 18 
7.4 Final resonance search ... 18 
7.5 Final measurements ... 18 
8 Shock, drop and topple ... 19 
9 Mounting position ... 19 
10 Over-range ... 20 
11 Output load effects ... 20 
11.1 Electrical output ... 20 
11.2 Pneumatic output ... 21 
12 Power supply ... 21 
12.1 Supply voltage and frequency variations ... 21 
12.2 Transient supply voltage effects ... 22 
12.3 Supply voltage depression ... 22 
12.4 Short-term supply voltage interruptions ... 23 
12.5 Fast transient/burst immunity requirements ... 24 
12.6 Surge immunity requirements ... 25 
12.7 Reverse supply voltage protection (d.c. devices) ... 25 
12.8 Supply pressure variations ... 25 
12.9 Supply pressure interruptions ... 26 
12.10 Conducted radio frequency requirements ... 26 
13 Electrical interference ... 27 
13.1 Common mode interference ... 27 
13.2 Series mode interference ... 27 
13.3 Earthing ... 27 
14 Harmonic distortion effects ... 27 
15 Magnetic field effects ... 28 
16 Electromagnetic field immunity test ... 30 
17 Electrostatic discharge ... 31 
18 Effect of open-circuited and short-circuited input ... 32 
19 Effect of open-circuited and short-circuited output ... 33 
20 Effects of process medium conditions ... 33 
20.1 Temperature of process fluid ... 33 
20.2 Flow of process fluid through the device ... 33 
20.3 Static line pressure effect ... 34 
21 Atmospheric pressure effects ... 35 
22 Flow of purge gas through the device ... 35 
23 Accelerated operational life test ... 35 
24 Operational long-term drift test (optional) ... 36 
Bibliography ... 38 
Foreword
GB/T 18271 "Process measurement and control devices - General methods
and procedures for evaluating performance" is currently planned to be issued
as follows:
- Part 1: General considerations;
- Part 2: Tests under reference conditions;
- Part 3: Tests for the effects of influence quantities;
- Part 4: Evaluation report content.
This Part is Part 3 of GB/T 18271.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/T 18271.3-2000 "Process measurement and control
devices - General methods and procedures for evaluating performance - Part
3: Tests for the effects of influence quantities". Compared with GB/T 18271.3-
2000, the main technical changes of this Part are as follows:
- UPDATE normative references (see Clause 2; Clause 2 of the 2000 edition);
- Delete the term "device under test" and definition (see 3.1 of the 2000
edition);
- ADD the term "type test" and definition (see 3.8);
- ADD the requirement that “A test is only to be performed if it is applicable
to the Device Under Test (DUT). If the specification of the DUT states limits
for the influence considered, these limits shall be noted and respected” (see
4.1);
- ADD general requirements for electromagnetic compatibility test (see 4.3);
- Modify the temperature range, temperature class, and typical service
application in Table 1 "Ambient temperature test ranges" and add a note
(see Table 1; Table 1 of the 2000 edition);
- Modify the typical application and the parameter of vibration levels in Table
2 "Vibration test levels" (see Table 2; Table 2 of the 2000 edition);
- Modify the test voltage and frequency values in "Supply voltage and
frequency variations" (see 12.1; 12.1 of the 2000 edition);
- In "Short-term supply voltage interruptions", delete the requirements that
"The a.c. power supply unit shall be interrupted for 1, 5, 10, and 25 cycle
durations at the crossover point" and "In addition, random interruptions can
also be used for at least 10 times each duration"; CHANGE to the provision
that the tests shall be according to the requirements of 4.3; and, add the
test parameters of power supply commutations-interruptions (see 4.3; 12.4
of the 2000 edition);
- Modify "Fast transient/burst immunity" test requirements; ADD the provision
that the tests shall be according to the requirements of 4.3; CHANGE
"severity level specified by the manufacturer" to "severity level according to
Table 2 of GB/T 18268.1-2010"; and, add Table 5 "Burst characteristics"
(see 12.5; 12.5 of the 2000 edition);
- Modify "Surge immunity" test requirements; ADD the provision that the tests
shall be according to the requirements of 4.3; CHANGE "severity level
specified by the manufacturer" to "severity level according to Table 2 of
GB/T 18268.1-2010"; amend "Input level shall be maintained at a value that
produces 50 % of the output signal" to "The device input shall be held
constant at 50 %"; and, add Table 6 "Surge characteristics" (see 12.6; 12.6
of the 2000 edition);
- ADD the provision that the tests shall be according to the requirements of
4.3 to "Supply pressure interruptions" (see 12.9);
- ADD the test method of "Conducted radio frequency requirements" (see
12.10);
- Delete the provisions regarding "Common mode interference" and "Series
mode interference" (see 13.1 and 13.2 of the 2000 edition);
- Modify the harmonic distortion test level in "Harmonic distortion effects"
from 2 % and 10 % TO 2 %, 5 %, 10 %, and 20 % (see Clause 14; Clause
14 of the 2000 edition);
- ADD the provision that "Magnetic field effects" test shall meet the
requirements of 4.3; CHANGE the test magnetic field strength from a
uniform 400 A/m (r.m.s) to "according to the relevant standards for the
environment in which it is located" (see Clause 15);
- Modify the title of Clause 16 from "Radiated electromagnetic interference"
to "Electromagnetic field immunity test"; ADD a provision that the test field
strength for the enclosure device is 10 V/m (see Clause 16; Clause 16 of
the 2000 edition);
- ADD the provision that the tests shall be according to the requirements of
4.3 to "Electrostatic discharge"; MAKE clear that a severity level, specified
in GB/T 18268.1-2010, is defined for the enclosure device equivalent to 4
kV / 8 kV contact/air (see Clause 17);
- CHANGE "Operational long-term drift test" to optional (see Clause 24);
- ADD bibliography.
This Part, using translation method, is identical to IEC 61298-3:2008 "Process
measurement and control devices - General methods and procedures for
evaluating performance - Part 3: Tests for the effects of influence quantities".
China’s documents which have a consistent correspondence...