1
/
von
9
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
GB/T 17626.2-2018 English PDF (GBT17626.2-2018)
GB/T 17626.2-2018 English PDF (GBT17626.2-2018)
Normaler Preis
$655.00 USD
Normaler Preis
Verkaufspreis
$655.00 USD
Grundpreis
/
pro
Versand wird beim Checkout berechnet
Verfügbarkeit für Abholungen konnte nicht geladen werden
Delivery: 3 seconds. Download true-PDF + Invoice.
Get QUOTATION in 1-minute: Click GB/T 17626.2-2018
Historical versions: GB/T 17626.2-2018
Preview True-PDF (Reload/Scroll if blank)
GB/T 17626.2-2018: Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 17626.2-2018
Electromagnetic compatibility--Testing and measurement techniques--Electrostatic discharge immunity test
ICS 33.100.20
L06
National Standards of People's Republic of China
Replace GB/T 17626.2-2006
Electromagnetic compatibility test and measurement technology
Electrostatic discharge immunity test
[IEC 61000-4-2.2008, Electromagneticcompatibility(EMC)-Part 4-2.
Test,IDT]
2018-06-07 released.2019-01-01 implementation
State market supervision and administration
China National Standardization Administration issued
Content
Foreword I
1 range 1
2 Normative references 1
3 Terms and Definitions 1
4 Overview 3
5 Test level 3
6 test generator 4
6.1 Overview 4
6.2 Characteristics of Electrostatic Discharge Generators 5
6.3 Verification of ESD Arrangement 7
7 test arrangement 8
7.1 Test equipment 8
7.2 Arrangement of laboratory tests 8
7.3 Arrangement for post-installation test 12
8 Test procedure 14
8.1 Laboratory Reference Conditions 14
8.2 Assessment of the equipment under test 14
8.3 Implementation of the test 14
9 Evaluation of test results 16
10 Test report 17
Appendix A (informative) Description 18
Appendix B (Normative) Calibration and discharge current measurement for current measurement systems 22
Appendix C (informative) Example of a calibration target that meets the requirements of Annex B 27
Appendix D (informative) Radiation field generated by human metal discharge and electrostatic discharge generators 32
Appendix E (informative) Measurement uncertainty (MU) considerations 40
Appendix F (informative) Changes in test results and adjustment strategies 46
Reference 47
Foreword
GB/T 17626 "Electromagnetic Compatibility Test and Measurement Technology" currently includes the following parts.
---GB/T 17626.1-2006 Electromagnetic compatibility test and measurement technology immunity test;
---GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test;
---GB/T 17626.4-2018 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test;
---GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology surge (impact) immunity test;
---GB/T 17626.6-2017 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction;
---GB/T 17626.7-2008 Electromagnetic compatibility test and measurement technology Power supply system and connected equipment Harmonic, interharmonic wave measurement and
Guide to measuring instruments;
---GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology power frequency magnetic field immunity test;
---GB/T 17626.9-2011 Electromagnetic compatibility test and measurement technology pulse magnetic field immunity test;
---GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology damping magnetic field immunity test;
---GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology Immunity of voltage dips, short interruptions and voltage changes
test;
---GB/T 17626.12-2013 Electromagnetic compatibility test and measurement technology ringing wave immunity test;
---GB/T 17626.13-2006 Electromagnetic compatibility test and measurement technology AC power port harmonics, interharmonics and grid signals
Low frequency immunity test;
---GB/T 17626.14-2005 Electromagnetic compatibility test and measurement technology voltage fluctuation immunity test;
---GB/T 17626.15-2011 Electromagnetic compatibility test and measurement technology scintillator function and design specifications;
---GB/T 17626.16-2007 Electromagnetic compatibility test and measurement technology 0Hz~150kHz common mode conducted disturbance immunity
test;
---GB/T 17626.17-2005 Electromagnetic compatibility test and measurement technology DC power input port ripple immunity test;
---GB/T 17626.18-2016 Electromagnetic compatibility test and measurement technology damping oscillatory wave immunity test;
---GB/T 17626.20-2014 Electromagnetic Compatibility Test and Measurement Technology Emission and Immunity in Transverse Electromagnetic Wave (TEM) Waveguides
Degree test
---GB/T 17626.21-2014 Electromagnetic compatibility test and measurement technology mixing chamber test method;
---GB/T 17626.22-2017 Electromagnetic compatibility test and measurement technology Radiation emission and immunity in full anechoic chamber
measuring;
---GB/T 17626.24-2012 Electromagnetic compatibility test and measurement technology Test of HEMP conducted disturbance protection device
method;
---GB/T 17626.27-2006 Electromagnetic compatibility test and measurement technology three-phase voltage unbalance immunity test;
---GB/T 17626.28-2006 Electromagnetic compatibility test and measurement technology power frequency change immunity test;
---GB/T 17626.29-2006 Electromagnetic compatibility test and measurement technology DC power input port voltage dip, short interruption and
Immunity test for voltage changes;
---GB/T 17626.30-2012 Electromagnetic compatibility test and measurement technology power quality measurement method;
---GB/T 17626.34-2012 Electromagnetic compatibility test and measurement technology for main power supply per phase current greater than 16A
Voltage dip, short interruption and voltage variation immunity test.
This part is the second part of GB/T 17626.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 17626.2-2006 "Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test".
Compared with GB/T 17626.2-2006, the main technical changes are as follows.
--- Increased calibration procedures and measurement uncertainty in the range;
--- Added terminology. calibration, compliance testing, rise time, verification;
--- Chapter 5 test level description was modified;
--- Added charging switch to the test generator;
--- Modified the schematic diagram of the electrostatic discharge generator;
--- Increased the characteristics of the electrostatic discharge generator (see 6.2);
--- Added verification of ESD placement (see 6.3);
--- Added A.8 (see Appendix A);
--- Revised Appendix B for calibration and discharge current measurement of current measurement systems;
--- Added Appendix C to meet the requirements of Appendix B for current targets;
--- Added Appendix D, the human metal discharge and the radiation field generated by the electrostatic discharge generator;
--- Added Appendix E, Measurement Uncertainty (MU) considerations;
--- Added Appendix F, changes in test results and adjustment strategies.
This section uses the translation method equivalent to IEC 61000-4-2.2008 "Electromagnetic compatibility (EMC) Part 4-2. Test and measurement techniques
Electrostatic discharge immunity test.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
--- GB/T 2421-2008 Environmental testing of electrical and electronic products - Part 1. General (IEC 60068-1.1988, IDT).
This section has made the following editorial changes.
--- In line with the existing standard series, this part of the name was changed to "electromagnetic compatibility test and measurement technology electrostatic discharge immunity
test".
This part is proposed and managed by the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246).
This section drafted by. Shangh...
Get QUOTATION in 1-minute: Click GB/T 17626.2-2018
Historical versions: GB/T 17626.2-2018
Preview True-PDF (Reload/Scroll if blank)
GB/T 17626.2-2018: Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 17626.2-2018
Electromagnetic compatibility--Testing and measurement techniques--Electrostatic discharge immunity test
ICS 33.100.20
L06
National Standards of People's Republic of China
Replace GB/T 17626.2-2006
Electromagnetic compatibility test and measurement technology
Electrostatic discharge immunity test
[IEC 61000-4-2.2008, Electromagneticcompatibility(EMC)-Part 4-2.
Test,IDT]
2018-06-07 released.2019-01-01 implementation
State market supervision and administration
China National Standardization Administration issued
Content
Foreword I
1 range 1
2 Normative references 1
3 Terms and Definitions 1
4 Overview 3
5 Test level 3
6 test generator 4
6.1 Overview 4
6.2 Characteristics of Electrostatic Discharge Generators 5
6.3 Verification of ESD Arrangement 7
7 test arrangement 8
7.1 Test equipment 8
7.2 Arrangement of laboratory tests 8
7.3 Arrangement for post-installation test 12
8 Test procedure 14
8.1 Laboratory Reference Conditions 14
8.2 Assessment of the equipment under test 14
8.3 Implementation of the test 14
9 Evaluation of test results 16
10 Test report 17
Appendix A (informative) Description 18
Appendix B (Normative) Calibration and discharge current measurement for current measurement systems 22
Appendix C (informative) Example of a calibration target that meets the requirements of Annex B 27
Appendix D (informative) Radiation field generated by human metal discharge and electrostatic discharge generators 32
Appendix E (informative) Measurement uncertainty (MU) considerations 40
Appendix F (informative) Changes in test results and adjustment strategies 46
Reference 47
Foreword
GB/T 17626 "Electromagnetic Compatibility Test and Measurement Technology" currently includes the following parts.
---GB/T 17626.1-2006 Electromagnetic compatibility test and measurement technology immunity test;
---GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test;
---GB/T 17626.4-2018 Electromagnetic compatibility test and measurement technology Electrical fast transient burst immunity test;
---GB/T 17626.5-2008 Electromagnetic compatibility test and measurement technology surge (impact) immunity test;
---GB/T 17626.6-2017 Electromagnetic compatibility test and measurement technology Conducted disturbance immunity of RF field induction;
---GB/T 17626.7-2008 Electromagnetic compatibility test and measurement technology Power supply system and connected equipment Harmonic, interharmonic wave measurement and
Guide to measuring instruments;
---GB/T 17626.8-2006 Electromagnetic compatibility test and measurement technology power frequency magnetic field immunity test;
---GB/T 17626.9-2011 Electromagnetic compatibility test and measurement technology pulse magnetic field immunity test;
---GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology damping magnetic field immunity test;
---GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology Immunity of voltage dips, short interruptions and voltage changes
test;
---GB/T 17626.12-2013 Electromagnetic compatibility test and measurement technology ringing wave immunity test;
---GB/T 17626.13-2006 Electromagnetic compatibility test and measurement technology AC power port harmonics, interharmonics and grid signals
Low frequency immunity test;
---GB/T 17626.14-2005 Electromagnetic compatibility test and measurement technology voltage fluctuation immunity test;
---GB/T 17626.15-2011 Electromagnetic compatibility test and measurement technology scintillator function and design specifications;
---GB/T 17626.16-2007 Electromagnetic compatibility test and measurement technology 0Hz~150kHz common mode conducted disturbance immunity
test;
---GB/T 17626.17-2005 Electromagnetic compatibility test and measurement technology DC power input port ripple immunity test;
---GB/T 17626.18-2016 Electromagnetic compatibility test and measurement technology damping oscillatory wave immunity test;
---GB/T 17626.20-2014 Electromagnetic Compatibility Test and Measurement Technology Emission and Immunity in Transverse Electromagnetic Wave (TEM) Waveguides
Degree test
---GB/T 17626.21-2014 Electromagnetic compatibility test and measurement technology mixing chamber test method;
---GB/T 17626.22-2017 Electromagnetic compatibility test and measurement technology Radiation emission and immunity in full anechoic chamber
measuring;
---GB/T 17626.24-2012 Electromagnetic compatibility test and measurement technology Test of HEMP conducted disturbance protection device
method;
---GB/T 17626.27-2006 Electromagnetic compatibility test and measurement technology three-phase voltage unbalance immunity test;
---GB/T 17626.28-2006 Electromagnetic compatibility test and measurement technology power frequency change immunity test;
---GB/T 17626.29-2006 Electromagnetic compatibility test and measurement technology DC power input port voltage dip, short interruption and
Immunity test for voltage changes;
---GB/T 17626.30-2012 Electromagnetic compatibility test and measurement technology power quality measurement method;
---GB/T 17626.34-2012 Electromagnetic compatibility test and measurement technology for main power supply per phase current greater than 16A
Voltage dip, short interruption and voltage variation immunity test.
This part is the second part of GB/T 17626.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 17626.2-2006 "Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test".
Compared with GB/T 17626.2-2006, the main technical changes are as follows.
--- Increased calibration procedures and measurement uncertainty in the range;
--- Added terminology. calibration, compliance testing, rise time, verification;
--- Chapter 5 test level description was modified;
--- Added charging switch to the test generator;
--- Modified the schematic diagram of the electrostatic discharge generator;
--- Increased the characteristics of the electrostatic discharge generator (see 6.2);
--- Added verification of ESD placement (see 6.3);
--- Added A.8 (see Appendix A);
--- Revised Appendix B for calibration and discharge current measurement of current measurement systems;
--- Added Appendix C to meet the requirements of Appendix B for current targets;
--- Added Appendix D, the human metal discharge and the radiation field generated by the electrostatic discharge generator;
--- Added Appendix E, Measurement Uncertainty (MU) considerations;
--- Added Appendix F, changes in test results and adjustment strategies.
This section uses the translation method equivalent to IEC 61000-4-2.2008 "Electromagnetic compatibility (EMC) Part 4-2. Test and measurement techniques
Electrostatic discharge immunity test.
The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows.
--- GB/T 2421-2008 Environmental testing of electrical and electronic products - Part 1. General (IEC 60068-1.1988, IDT).
This section has made the following editorial changes.
--- In line with the existing standard series, this part of the name was changed to "electromagnetic compatibility test and measurement technology electrostatic discharge immunity
test".
This part is proposed and managed by the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246).
This section drafted by. Shangh...
Share